5.6 F: Option Settings
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
265
5
■
F6-08: Reset Communication Parameters
Determines whether communication-related parameters (F6-
/F7-
) are reset when the drive is initialized using
parameter A1-03.
Setting 0: Do not reset parameters F6-
/F7-
when the drive is initialized with A1-03
Setting 1: Reset F6-
/F7-
when the drive is initialized with A1-03
Note:
F6-08 is not reset when the drive is initialized.
■
CC-Link Parameters
Parameters F6-04, F6-10, F6-11, and F6-14 set up the drive to operate on a CC-Link network.
For details on parameter settings, refer to the YASKAWA AC Drive 1000-Series Option CC-Link Installation Manual
and Technical Manual.
■
MECHATROLINK-II Parameters
Parameters F6-20 through F6-26 set up the drive to operate on a MECHATROLINK-II network.
For details on parameter settings, refer to the YASKAWA AC Drive 1000-Series Option MECHATROLINK-II
Installation Manual and Technical Manual.
■
MECHATROLINK-III Parameters
Parameters F6-20, F6-21, F6-23 through F6-26 set up the drive to operate on a MECHATROLINK-III network.
For details on parameter settings, refer to the YASKAWA AC Drive 1000-Series Option MECHATROLINK-III
Installation Manual and Technical Manual.
■
PROFIBUS-DP Parameters
Parameters F6-30 through F6-32 set up the drive to operate on a PROFIBUS-DP network.
For details on parameter settings, refer to the YASKAWA AC Drive 1000-Series Option PROFIBUS-DP Installation
Manual and Technical Manual.
■
CANopen Parameters
Parameters F6-35 and F6-36 set up the drive to operate on a CANopen network.
For details on parameter settings, refer to the YASKAWA AC Drive 1000-Series Option CANopen Installation Manual
and Technical Manual.
■
DeviceNet Parameters
Parameters F6-50 through F6-63 set up the drive to operate on a DeviceNet network.
For details on parameter settings, refer to the YASKAWA AC Drive 1000-Series Option DeviceNet Installation Manual
and Technical Manual.
■
Modbus TCP/IP Parameters
Parameters F7-01 through F7-16, U6-80 through U6-93, U6-98, and U6-99 set up the drive to operate on a Modbus TCP/
IP network.
For details on parameter settings, refer to the YASKAWA AC Drive 1000-Series Option Modbus TCP/IP Installation
Manual and Technical Manual.
■
EtherNet/IP Parameters
Parameters F7-01 through F7-15, F7-17 through F7-42, U6-80 through U6-93,U6-98, and U6-99 set up the drive to
operate on an EtherNet/IP network.
For details on parameter settings, refer to the YASKAWA AC Drive 1000-Series Option EtherNet/IP Installation Manual
and Technical Manual.
No.
Parameter Name
Setting Range
Default
F6-08
Reset Communication Parameters
0, 1
0
SIEP_C710636_02B_1_0.book 265 ページ 2015年11月25日 水曜日 午後4時56分