4.6 Application Selection
150
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
Table 4.13 HVAC Fan: User Parameters (A2-01 to A2-16)
◆
Setting 5: Air Compressor Application
Table 4.14 Compressor: Parameter Settings
Table 4.15 Compressor: User Parameters (A2-01 to A2-16):
◆
Setting 6: Hoist Application
Note: 1.
Read the instructions listed on page
when using Hoist Application Preset
2.
Perform Auto-Tuning after selecting the Hoist Application Preset.
Table 4.16 Hoist: Parameters and Settings
No.
Parameter Name
No.
Parameter Name
b1-01
Frequency Reference Selection 1
d2-02
Frequency Reference Lower Limit
b1-02
Run Command Selection 1
E1-03
V/f Pattern Selection
b1-03
Stopping Method Selection
E1-04
Maximum Output Frequency
b1-04
Reverse Operation Selection
E2-01
Motor Rated Current
C1-01
Acceleration Time 1
H3-11
Terminal A2 Gain Setting
C1-02
Deceleration Time 1
H3-12
Terminal A2 Bias Setting
C6-02
Carrier Frequency Selection
L2-01
Momentary Power Loss Operation Selection
d2-01
Frequency Reference Upper Limit
o4-12
kWh Monitor Initialization
No.
Parameter Name
Default Setting
A1-02
Control Method Selection
0: V/f Control
b1-04
Reverse Operation Selection
1: Reverse Prohibited
C1-01
Acceleration Time 1
5.0 s
C1-02
Deceleration Time 1
5.0 s
C6-01
Drive Duty Model Selection
0: Heavy Duty (HD)
E1-03
V/f Pattern Selection
F: Custom V/f pattern
L2-01
Momentary Power Loss Operation Selection
1: Enabled
No.
Parameter Name
No.
Parameter Name
b1-01
Frequency Reference Selection 1
E1-03
V/f Pattern Selection
b1-02
Run Command Selection 1
E1-07
Middle Output Frequency
b1-04
Reverse Operation Selection
E1-08
Middle Output Frequency Voltage
C1-01
Acceleration Time 1
E2-01
Motor Rated Current
C1-02
Deceleration Time 1
−
−
No.
<1> Max. setting value varies by the drive model selection (o2-04).
Parameter Name
Default Setting
A1-02
Control Method Selection
2: Open Loop Vector Control
b1-01
Frequency Reference Selection 1
0: Operator
b6-01
Dwell Reference at Start
3.0 Hz
b6-02
Dwell Time at Start
0.3 s
C1-01
Acceleration Time 1
3.0 s
C1-02
Deceleration Time 1
3.0 s
C6-01
Drive Duty Mode Selection
0: Heavy Duty (HD)
C6-02
Carrier Frequency Selection
2: 6.0 kHz
d1-01
Frequency Reference 1
6.0 Hz
d1-02
Frequency Reference 2
30.0 Hz
d1-03
Frequency Reference 3
60.0 Hz
E1-03
V/f Pattern Selection
F: Custom V/f pattern
H2-01
Terminals M1-M2 Function Selection
5: Frequency Detection 2
H2-02
CIMR-UA
, CIMR-UD
, CIMR-UT
:Terminal P1-PC Function Selection
(Open-collector)
CIMR-UB
:Terminal M3-M4 Function Selection (Relay)
37: During Frequency Output
H3-06
Terminal A3 Function Selection
1F: Through mode
L2-03
Momentary Power Loss Minimum Baseblock Time
0.3 s
L4-01
Speed Agreement Detection Level
2.0 Hz
L4-02
Speed Agreement Detection Width
0.0 Hz
L6-01
Torque Detection Selection 1
8: UL3, UL4 at speed agree (fault)
L6-02
Torque Detection Level 1
2%
L6-03
Torque Detection Time 1
0.5 s
L8-07
Output Phase Loss Protection Selection
1: Enabled
L8-38
Carrier Frequency Reduction Selection
1: Enabled below 6 Hz
L8-41
High Current Alarm Selection
1: Enabled (alarm is output)