4.7 Auto-Tuning
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
165
St
ar
t-
Up Pr
ogr
ammi
ng
&
O
p
er
at
io
n
4
■
T2-05: PM Motor Rated Voltage
Sets the motor rated voltage.
■
T2-06: PM Motor Rated Current
Enter the motor rated current in amps.
■
T2-07: PM Motor Base Frequency
Enter the motor base frequency in Hz.
Note:
T2-07 will be displayed when in OLV/PM.
■
T2-08: Number of PM Motor Poles
Enter the number of motor poles.
■
T2-09: PM Motor Base Speed
Enter the motor rated speed in min
-1
.
Note:
T2-09 will be displayed when in AOLV/PM and CLV/PM.
■
T2-10: PM Motor Stator Resistance
Enter the motor stator resistance per motor phase.
■
T2-11: PM Motor d-Axis Inductance
Enter the d axis inductance per motor phase.
No.
Name
Setting Range
Default
<1> The setting range and default value shown here is for a 200 V class drive. These values double when using a 400 V class unit.
T2-05
PM Motor Rated Voltage
0.0 to 255.0 V
200.0 V
No.
Name
Setting Range
Default
T2-06
PM Motor Rated Current
10% to 150% of the drive rated
current.
Depending on o2-04
No.
Name
Setting Range
Default
T2-07
PM Motor Base Frequency
0.0 to 400.0 Hz
87.5 Hz
No.
Name
Setting Range
Default
T2-08
Number of PM Motor Poles
2 to 48
6
No.
Name
Setting Range
Default
T2-09
PM Motor Base Speed
0 to 24000 min
-1
1750 min
-1
No.
Name
Setting Range
Default
T2-10
PM Motor Stator Resistance
0.000 to 65.000
Ω
Depending on T2-02
No.
Name
Setting Range
Default
T2-11
PM Motor d-Axis Inductance
0.00 to 600.00 mH
Depending on T2-02