![YASKAWA U1000 Series Скачать руководство пользователя страница 379](http://html.mh-extra.com/html/yaskawa/u1000-series/u1000-series_technical-manual_907114379.webp)
6.7 Auto-Tuning Fault Detection
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
379
T
rou
bl
es
hoot
ing
6
Digital Operator Display
Error Name
Er-25
High Frequency Injection Parameter Tuning Error
Cause
Possible Solutions
Motor data was incorrect.
Perform Stationary Auto-Tuning and then perform High Frequency Injection Parameter Tuning again. If the problem continues, high
frequency injection control might not be possible with that motor.
Note:
Auto-Tuning is not applicable for SPM motors.