![YASKAWA U1000 Series Скачать руководство пользователя страница 413](http://html.mh-extra.com/html/yaskawa/u1000-series/u1000-series_technical-manual_907114413.webp)
7.4 Cooling Fan and Circulation Fan
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
413
Pe
ri
odi
c
In
s
p
ec
ti
on
&
Mainten
ance
7
3.
Loosen the twenty five screws that hold the drive cover 2 in place and free it from the drive.
CAUTION!
Crush Hazard. Do not completely remove the cover screws, just loosen them. If the cover screws are removed completely,
the terminal cover may fall off causing an injury. Take special care when removing/reattaching the terminal covers for larger drives.
Figure 7.39
Figure 7.39 Remove the Drive Cover 2
4.
Unplug the relay connectors and free the cable from the cooling fan unit.
Figure 7.40
Figure 7.40 Unplug the Relay Connector
Twenty-five-screw locations
SIEP_C710636_02B_1_0.book 413 ページ 2015年11月25日 水曜日 午後4時56分