USO
RESTRITO
342
Applying Special Effects (Lighting and Recursive Effects)
Knob
Parameter
Adjustment
Setting values
1
Shape Ptn Shape pattern
1 to 2
a)
2
Size
Shape size
0.00 to 24.00
3
Deform
Amount of
shape
deformation
0.00 to 100.00
b)
4
Soft
Softness of
shape pattern
0.00 to 100.00
5
Angle
Angle of shape
pattern rotation
–8.00 to +8.00
c)
Knob
Parameter
Adjustment
Setting values
1
Offset
Offset from
center position
(radius)
–24.00 to
+24.00
2
Radius
Radius of ring
0.00 to 6.00
3
Angle
Rotation angle
of ring
–8.00 to +8.00
a)
in the Appendix.
Ch
a
p
te
r 11
DM
E
O
p
e
ra
ti
o
n
s
the light effect is not applied to the background, even if
you select BKGD or Both.
•
If the setting of [Brilliancy] in the <Fill Source> group
of the Light Color Adjust menu
is 100.00,
the light effect is not applied to the background, even if
you select BKGD or Both.
•
When the global effect Combiner is set to Mix or Depth,
the light effect is not applied to the background, even if
you select BKGD or Both.
To select Surface Flat
Press [Surface Flat], turning it on.
If you have selected anything other than Flat in the
<Surface Select> group of the Spot Lighting menu, the
part corresponding only to the surface being struck by the
currently set light from the light source is shown in the
same way as if Flat had been selected.
To set the shape of the light
1
Press [Shape], turning it on.
2
Set the following parameters.
SD format
Knob
Parameter
Adjustment
Setting values
1
Shape Ptn Shape pattern
1 to 2
a)
2
Size
Shape size
0.00 to 6.00
3
Deform
Amount of
shape
deformation
0.00 to 100.00
b)
4
Soft
Softness of
shape pattern
0.00 to 100.00
5
Angle
Angle of shape
pattern rotation
–8.00 to +8.00
c)
a)
For more information about the shape patterns, see “Shape Patterns”
in the Appendix.
b)
0 is a round shape, and 100 is the shape of the pattern. Smaller values
make the pattern more rounded.
c)
–
1.00 is one rotation in the counterclockwise direction. +1.00 is one
rotation in the clockwise direction.
HD format
c)
–
1.00 is one rotation in the counterclockwise direction. +1.00 is one
rotation in the clockwise direction.
To rotate the shape pattern
1
Press [Shape Speed], turning it on.
The display on knob 5 that was visible when [Shape]
was selected changes.
2
Set the following parameter.
Knob
Parameter
Adjustment
Setting values
5
Speed
Rotation
direction and
speed
–100.00 to
+100.00
a)
a)
–
100.00 is four rotations per second in the counterclockwise
direction, and +100.00 is four rotations per second in the clockwise
direction. 0.00 stops the rotation.
To change the light to a ring shape
Notes
If you select Parallel or Whole
in the <Spot
Mode> group and shaping is disabled, the Ring parameter
cannot be set.
1
Press [Ring], turning it on.
2
Set the following parameter.
SD format
Knob
Parameter
Adjustment
Setting values
1
Offset
Offset from
center
position
(radius)
–6.00 to +6.00
2
Radius
Radius of
ring
0.00 to 6.00
3
Angle
Rotation
angle of ring
–8.00 to +8.00
a)
a)
–
1.00 is one rotation in the counterclockwise direction and +1.00 is
one rotation in the clockwise direction.
Notes
There is no Radius setting when Line is selected in the
<Spot Mode> group.
HD format
a)
For more information about the shape patterns, see “Shape Patterns”
b)
0 is a round shape, and 100 is the shape of the pattern. Smaller values
make the pattern more rounded.
Содержание MVS-8000X SystemMVS-7000X System
Страница 358: ...USO RESTRITO 358 Wipe Pattern List Appendix Volume 1 Enhanced Wipes Rotary Wipes ...
Страница 360: ...USO RESTRITO Random Diamond DustWipes 360 1 w pe PaternLO ...
Страница 362: ...USO RESTRITO 362 DME Wipe Pattern List Appendix Volume 1 Door 2D trans 3D trans ...
Страница 363: ...USO RESTRITO DME Wipe Pattern List 363 Appendix Volume 1 Flip tumble Frame in out Picture in picture ...
Страница 364: ...USO RESTRITO 364 DME Wipe Pattern List Appendix Volume 1 Page turn Page roll ...
Страница 365: ...USO RESTRITO DME Wipe Pattern List 365 Appendix Volume 1 Mirror Sphere Character trail Wave Ripple Split slide ...
Страница 367: ...USO RESTRITO DME Wipe Pattern List 367 Appendix Volume 1 Squeeze 3D trans Picture in picture Page turn ...
Страница 376: ...USO RESTRITO 376 Menu Tree Appendix Volume 1 Frame Memory Menu FRAME MEM button Color Bkgd Menu COLOR BKGD button ...
Страница 377: ...USO RESTRITO Menu Tree 377 Appendix Volume 1 AUX Menu AUX button CCR Menu CCR button ...
Страница 379: ...USO RESTRITO Menu Tree 379 Appendix Volume 1 DME Menu DME button ...
Страница 380: ...USO RESTRITO 380 Menu Tree Appendix Volume 1 Global Effect Menu GLB EFF button Router Menu Device Menu DEV button ...
Страница 381: ...USO RESTRITO Menu Tree 381 Appendix Volume 1 Macro Menu MCRO button ...
Страница 382: ...USO RESTRITO 382 Menu Tree Appendix Volume 1 Key Frame Menu KEY FRAME button ...
Страница 383: ...USO RESTRITO Menu Tree 383 Appendix Volume 1 Effect Menu EFF button ...
Страница 384: ...USO RESTRITO 384 Menu Tree Appendix Volume 1 Snapshot Menu SNAPSHOT button ...
Страница 385: ...USO RESTRITO Menu Tree 385 Appendix Volume 1 Shotbox Menu SHOTBOX button ...
Страница 386: ...USO RESTRITO 386 Menu Tree Appendix Volume 1 File Menu FILE button ...
Страница 388: ...USO RESTRITO 388 Menu Tree Appendix Volume 1 ENG SETUP button to previous page topages after 390 to next page ...
Страница 389: ...USO RESTRITO Menu Tree 389 Appendix Volume 1 ENG SETUP button to page 387 to previous pages to following pages ...
Страница 390: ...USO RESTRITO 390 Menu Tree Appendix Volume 1 ENG SETUP button to previous pages to next page a MVS 7000X only ...
Страница 391: ...USO RESTRITO Menu Tree 391 Appendix Volume 1 ENG SETUP button to previous pages ...
Страница 392: ...USO RESTRITO 392 Menu Tree Appendix Volume 1 User Setup Menu USER SETUP button Diagnostic Menu DIAG button ...
Страница 413: ...USO RESTRITO MVS 8000X System MVS 7000X System SY 4 470 637 01 1 Sony Corporation 2013 ...
Страница 706: ...USO RESTRITO MVS 8000X System MVS 7000X System SY 4 470 637 01 1 Sony Corporation 2013 ...