Function modules
8.8 Basic positioner
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
525
Instructions for data set changeover
Using drive data set changeover (DDS), motor data sets (MDS, p0186) and encoder data
sets (EDS, p0187 to p0189) can be changed over. The following table shows when the
reference bit (r2684.11) or the status of the adjustment with absolute encoders (p2507) is
reset.
In the following cases, when a DDS changeover takes place, the actual position value
becomes invalid (p2521 = 0) and the reference point (r2684.11 = 0) is reset.
●
The EDS that is effective for the position control changes.
●
The encoder assignment changes (p2502).
●
The mechanical relationships change (p2503...p2506)
With absolute encoders, the status of the adjustment (p2507) is also reset, if the same
absolute encoder is selected for the position control although the mechanical relationships
have changed (p2503 ... p2506).
In the operation state, a fault (F07494) is also output.
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......