Basic functions
7.24 Terminal Module 41
Drive functions
398
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
7.24
Terminal Module 41
Terminal Module 41 is characterized by the following features:
●
Pulse encoder emulation, TTL signals according to the RS422 standard (X520)
●
1 analog input
●
4 digital inputs
●
4 bidirectional digital inputs/outputs
Terminal Module 41 (TM41) emulates incremental encoder signals (TTL) - and outputs them
via interface X520. The signals are based on speed setpoints transferred via process data
words (SIMOTION mode) or created on the actual position value of a leading encoder
(SINAMICS mode). The emulated incremental encoder signal can be used by external
hardware or a higher-level controller.
The number of pulses output (virtual pulses) per revolution can be set over a wide range.
With the additional inputs and outputs, these can be used for example to transfer analog
speed setpoints or control and status signals, for example OFF1/ON, "ready for operation" or
"fault".
7.24.1
SIMOTION mode
The SIMOTION mode of the incremental encoder emulation is set using parameter p4400 =
0. The incremental encoder emulation is based on the speed setpoint.
A speed setpoint r2060 is received via PROFIdrive telegram 3, which is interconnected to
p1155. The speed setpoint can be filtered using a (p1414.0) PT2 element that can be
activated (p1417 and p1418). The speed setpoint can be delayed with the dead time p1412.
The number of encoder pulses per revolution can be set using parameter p0408. The
distance between the zero marks and the position when enabling the A/B tracks (r4402.1) is
entered into parameter p4426 and enabled with p4401.0 = 1.
Figure 7-18 Function diagram encoder emulation
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......