Basic functions
7.24 Terminal Module 41
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
405
Detecting the zero mark position for new synchronization
If the number of encoder pulses has not been set equal to 2
n
(for example p0408 = 1000),
then after the higher-level controller has been reset, it is possible that the position of the next
zero mark cannot be determined from the actual position value xACT1 signaled from the
TM41. For this situation, the control can query the position of the next zero mark from
parameter r4427 using an acyclic read request.
7.24.5
Limit frequencies for TM41
●
Adjustable pulse number (p0408): 32 to 16384 pulses/revolution (factory setting = 2048)
●
The maximum pulse frequencies (limit frequencies) specified in the tables below must not
be exceeded.
Table 7- 12 Maximum output frequencies for TM41 = 750 kHz (p4401.7 = 0)
Higher setpoint resolution not activated (p4401.5 = 0)
Sampling time p4099[3]
125 µs
250 µs
500 µs
Resolution
31.25 Hz
15.625 Hz
7.8125 Hz
SINAMICS mode
p4400 = 1
Output frequency f
max
(p0418 < 17 bit)
1024 kHz
512 kHz
256 kHz
Output frequency f
max
(p0418 = 17 bit)
512 kHz
256 kHz
128 kHz
Output frequency f
max
(p0418 = 18 bit)
256 kHz
128 kHz
64 kHz
SIMOTION mode
p4400 = 0
Output frequency f
max
1024 kHz
512 kHz
256 kHz
Table 7- 13 Maximum output frequencies for TM41 = 1024 kHz (p4401.7 = 1)
Higher setpoint resolution activated (p4401.5 = 1)
Sampling time p4099[3]
125 µs
250 µs
500 µs
Resolution
0.122 Hz
0.061 Hz
0.031 Hz
SINAMICS mode
p4400 = 1
Output frequency f
max
(p0418 < 17 bit)
1024 kHz
512 kHz
256 kHz
Output frequency f
max
(p0418 = 17 bit)
512 kHz
256 kHz
128 kHz
Output frequency f
max
(p0418 = 18 bit)
256 kHz
128 kHz
64 kHz
SIMOTION mode
p4400 = 0
Output frequency f
max
1024 kHz
1024 kHz
1024 kHz
Following error monitoring
If the actual position can no longer follow the entered position setpoint characteristic, then
fault F35220 is output. In the SINAMICS mode, the frequency setpoint is limited to the
maximum output frequency. The maximum output frequency from the TM41 is transferred to
the Control Unit.
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......