Monitoring functions and protective functions
9.5 Thermal motor protection
Drive functions
642
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Important settings
The most important parameters for thermal motor model 1 and/or for the expansion of this
model are subsequently explained.
When the expansion is subsequently activated, the corresponding parameters of the
expansion are preassigned with the parameter values before activating the expansion.
Parameters for the following
settings:
Explanation
p0612.08 = 0 p0612.08 = 1
p0605
p5390
Alarm threshold
If the model motor temperature (r0632) exceeds the alarm thresh-
old, alarm A07012 "Drive: Motor temperature model 1/3 over-
temperature" is output
p0615
p5391
Fault threshold
If the model motor temperature (r0632) exceeds the fault threshold,
fault F07011 "Drive: Motor overtemperature" is output.
p0605
p0627 + 40°C
Rated temperature (winding)
Defines the rated overtemperature of the stator winding referred to
the ambient temperature.
1.333 (fixed
value)
p5350
Boost factor
Defines the boost factor for the copper losses at standstill.
p0612 = 0x1
p0612 =
0x101
Activation
Activates the motor module and/or additionally the expansion.
r0632
r0632
Actual temperature
Indicates the stator winding temperature of the motor temperature
model.
r0034
r0034
Motor utilization
Indicates the actual motor utilization level.
Taking into account the ambient temperature
If, for thermal motor model 1, a temperature sensor has not been the parameterized, then
motor module 1 automatically uses an ambient temperature of 20°C for the calculation. You
can enter one of these ambient temperatures deviating from the standard temperature as
follows:
1.
Activate the setting p0612.12 = 1.
This enables parameter p0613. The factory setting is 20° C.
2.
If you wish to take into account an ambient temperature, which deviates from the factory
setting, in the motor model, then enter the expected ambient temperature in p0613.
Note
When commissioning the motor, the setting p0612.12 = 1 is automatically activated. p0613
can be parameterized when required.
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......