Function modules
8.8 Basic positioner
Drive functions
542
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Overview of important parameters (see SINAMICS S120/S150 List Manual)
•
p1528[0...n]
CI: Torque limit, upper/motoring, scaling
•
p1529[0...n]
CI: Torque limit, lower/regenerative scaling
•
p1545[0...n]
BI: Activate travel to fixed stop
•
r2526.0...9
CO/BO: LR status word
•
p2622[0...n]
EPOS traversing block, task parameter
•
p2634[0...n]
EPOS fixed stop maximum permissible following error
•
p2635
EPOS fixed stop monitoring window
•
p2637
BI: EPOS fixed stop reached
•
p2638
BI: EPOS fixed stop outside monitoring window
•
r2683.0...14
CO/BO: EPOS status word 1
•
r2686[0...1]
CO: EPOS torque limit effective
•
r2686[0...1]
CO: EPOS force limiting active (for linear motors)
8.8.9
Direct setpoint input (MDI)
The "direct setpoint specification" function allows for positioning (absolute, relative) and
setup (endless position-controlled) by means of direct setpoint specification (e.g. via the PLC
using process data).
During traversing, the motion parameters can also be influenced (on-the-fly setpoint
acceptance) and an on-the-fly change can be undertaken between the Setup and Positioning
modes. The "direct setpoint specification" mode (MDI) can also be used if the axis is not
referenced in the "setup" or "relative positioning" modes, which means that "flying
referencing" (see the separate section), flying synchronization, and post-referencing are
possible.
The "direct setpoint specification" function is activated by p2647 = 1. A distinction is made
between two modes: "positioning" mode (p2653 = 0) and "setup" mode (p2653 = 1).
In "positioning" mode, the parameters (position, velocity, acceleration and deceleration) can
be used to carry out absolute (p2648 = 1) or relative (p2648 = 0) positioning with the
parameter p2690.
In the "setup" mode, using parameters (velocity, acceleration and deceleration) endless
closed-loop position control behavior can be carried out.
It is possible to make a flying changeover between the two modes.
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......