Function modules
8.7 Position control
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
495
Configuration of the load gear (p2720).
The following points can be set by configuring this parameter:
●
p2720.0: Activation of position tracking
●
p2720.1: Setting the axis type (linear axis or rotary axis)
Here, a rotary axis refers to a modulo axis; the modulo offset can be activated from a
higher-level controller or EPOS. With a linear axis, position tracking is mainly used to
extend the position area (see section: Virtual multiturn encoder (p2721).
●
p2720.2: Reset position
The position values stored in non-volatile memory are reset in response to the following
events:
–
When encoder replacement is detected.
–
When the configuration of the encoder data set (EDS) is modified.
–
When the absolute encoder is adjusted again.
Note
If position tracking of the load gear is activated with parameter p2720[0] = 1 (position gear
load tracking) after the encoder is adjusted (p2507 = 3), the adjustment will be reset.
If the encoder is adjusted again when load position tracking is active, the load gear position
will be reset (overflows).
The permissible position tracking range is mapped on the reproducible encoder range of
EPOS.
It is possible to activate position tracking for several DDS.
Virtual multiturn encoder (p2721)
The number of resolvable load rotations for a rotary absolute encoder with active position
tracking
can be set by means of the virtual multiturn resolution.
It is only editable for rotary axes.
With a rotary absolute encoder (p0404.1 = 1) with activated position tracking (p2720.0 = 1),
p2721 can be used to enter a virtual multiturn resolution.
Note
If the gear ratio is not equal to 1, then p2721 always refers to the load side. The virtual
resolution, which is required for the load, is then set here.
In the case of rotary axes, the virtual multiturn resolution (p2721) is preset to the multiturn
resolution value of the encoder (p0421) and can be altered.
Example: Singleturn encoder
Parameter p0421 is preset to p0421 = 1. However, parameter p2721 can be altered
subsequently, e.g. the user can program p2721 = 5. As a result, the encoder evaluation
initiates five load rotations before the same absolute value is achieved again.
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......