Basic information about the drive system
13.8 Know-how protection
Drive functions
980
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Absolute know-how protection
If you remove password p7766 from the exception list, it is no longer possible to enter or
change the password for know-how protection.
You must reset the drive unit to factory settings in order to regain access to the drive unit's
adjustable parameters. When restoring the factory settings, you lose what you have
configured in the drive unit, and you must recommission the drive unit.
Extending the exception list
1.
Using the
symbol on the PC, back up the drive unit settings.
2.
Go offline ( ).
3.
Using p7763, in the expert list, define the required number of parameters n (n = 1 … 500)
of the exception list.
4.
Save the project.
5.
Go online.
6.
Load the project to the drive unit using the
icon in order to make them effective.
7.
In p7764[0 … n-1], assign the required parameter numbers to the indices of p7763.
You have extended the exception list for know-how protection.
13.8.3.2
Activate know-how protection
Requirements
Before activating know-how protection, the following conditions must be met:
●
The drive unit has been fully commissioned.
●
You have generated the exception list for know-how protection (see Maintaining the list of
exceptions (Page 979)).
●
To guarantee know-how protection, you must ensure that the project does not remain at
the end user as a file.
Procedure
1.
Connect the drive unit to the programming device.
2.
Go online with STARTER.
If you have generated a project offline on your computer, you must load the project into
the drive unit and go online.
3.
Select the required drive unit in the project navigator of your STARTER project.
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......