Communication
11.1 Communication according to PROFIdrive
Drive functions
772
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Channel-related diagnostics
Channel-related diagnostics encompasses the following data:
Bit
7
6
5
4
3
2
1
0
Octet
Name
x
Header-
Byte
1
1)
0
1)
0 ... 63 (module number) including this byte
x + 1
1
2)
1
2)
0 (no component assignment)
x + 2
0
3)
0
3)
Message classes:
2 undervoltage
3 overvoltage
9 error
16 Hardware/software error
17 Line supply/filter faulted
18 DC-link overvoltage
19 Power electronics faulted
20 Electronic component overtemp.
21 Ground/phase fault detected
22 Motor overload
23 Commun. with controller faulted
24 Safety monit. Detected an error
25 Act. Position/speed value error
26 Internal communication faulted
27 Infeed faulted
28 Braking controller faulted
29 External signal state error
30 Application/function faulted
31 Parameterization/commiss. error
1)
≙ Channel
-related diagnostics
2)
≙ Input/output
3)
≙ "Channel type "non specific"
System response
Only one signal is generated if channel-related diagnostics identifies several faults belonging
to the same message class at the same drive object.
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......