Basic functions
7.5 Sine-wave filter
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
325
Table 7- 6
Parameter settings for sine-wave filters
Parameter number
Name
Setting
p0233
Power unit motor reactor
Filter inductance
p0234
Power unit sine-wave filter
capacitance
Filter capacitance
p0290
Power unit overload response
Disable pulse frequency reduction
p1082
Maximum speed
Fmax filter / pole pair number
p1800
Pulse frequency
Nominal pulse frequency of the filter
p1802
Modulator modes
Space vector modulation without
overload