Communication
11.2 Communication via PROFIBUS DP
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
777
11.2.1.2
Example: telegram structure for cyclic data transmission
Task
The drive system comprises the following drive objects:
●
Control Unit (CU_S)
●
Active Infeed (A_INF)
●
SERVO 1 (comprises a Single Motor Module and other components)
●
SERVO 2 (comprises a Double Motor Module terminal X1 and other components)
●
SERVO 3 (comprises a Double Motor Module terminal X2 and other components)
●
Terminal Board 30 (TB30)
The process data is to be exchanged between the drive objects and the higher-level
automation system.
Telegrams to be used:
●
Telegram 370 for Active Infeed
●
Standard telegram 6 for SERVO
●
User-defined for Terminal Board 30 for the three SERVO drives
Component and telegram structure
The predefined component structure results in the telegram structure shown in the following
diagram.
Figure 11-11 Component and telegram structure
You can check and change the sequence of the telegrams via p0978[0...24].
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......