Basic functions
7.25 Upgrade the firmware and project
Drive functions
412
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Updating the firmware or configuration
You can update the firmware and a configuration separately via a zip file. The configuration
data must have been zipped via STARTER (using the "Load to file system" function).
Firmware and configuration can also be updated together. For this reason, the “Select file"
field is present twice. The following description refers to the separate update of the firmware
or the configuration:
1.
Click the folder icon to the right of the “Select file" field.
2.
Select the zip file of the new firmware or configuration in a directory of the Web client.
The name of the firmware or the configuration file is then displayed in the “Select file"
field.
The following options are offered for the subsequent update:
Option
Description
No backup
The existing firmware/configuration is not saved before the update.
No test
The firmware/configuration in the downloaded archive is not checked for
consistency.
No reset
A reset of the firmware/configuration is not initiated after the download.
Delete all
All files are deleted on the memory card before the archive is unpacked.
Note: Activate this option only when updating the firmware. Important data
would be destroyed with this option when updating the configuration.
NOTICE: loss of data,
Only the "/install/sinamics" directory and the license key are then retained.
3.
Select all the required update options by clicking.
4.
Click the “Send update data" button.
During the update, a check is made as to whether there is sufficient free space on the
memory card. The state of the drive objects of the Control Unit is also checked.
–
As long as the configuration update is running, fault "F01070 project/firmware
download to the memory card in progress" is output by SINAMICS.
–
As soon as partition 1 and partition 2 are not consistent with each other, the following
alarm is output "A01073 POWER ON for backup copy to memory card required".
In both cases an entry is made in the diagnostic buffer of the Control Unit.
Note
The firmware download to the memory card can take several minutes.
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......