Appendix
A.6 Availability of SW functions
Drive functions
1072
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Table A- 22 New functions, firmware 2.5 or 2.5 SP1
No. SW function
SERVO
VECTOR HW component
1
DCC (Drive Control Chart) with graphical interconnection editor
(DCC-Editor):
•
Graphically configurable modules (logic, calculation and control
functions)
•
Module types that can be freely instantiated (flexible number of
components/devices)
•
Can be run on SIMOTION and SINAMICS controllers (DCC
SINAMICS, DCC SIMOTION)
x
x
-
2
Safety Integrated Extended Functions:
•
Safety functionality integrated in the drive, controllable via
PROFIsafe (PROFIBUS) or secure terminal module TM54F
•
STO Safe Torque Off (previously Safe Standstill (SH)
•
SBC Safe Brake Control
•
SS1 Safe Stop 1, STO after a delay time has expired, standstill
without torque
•
SOS Safe Operating Stop, safe standstill with full torque
•
SS2 Safe Stop 2; SOS after a delay time has expired, standstill
with full torque
•
SLS Safely Limited Speed
•
SSM Safe Speed Monitor, safe speed monitor feedback (n <
nx) on a secure output
Note:
The Safety Integrated Basic Functions STO and SBC have been
implemented as of V2.1 and SS1 as of V2.4 (control via onboard
terminals).
x
x
Safety Integrated
Extended Functions
only for:
•
Motor Modules
(6SL3...-.....-
0AA3)
•
CUA31
(6SL3040-0PA00-
0AA1)
3
EPOS function extensions:
•
Traversing blocks / new task: "Travel to fixed stop"
•
Traversing blocks / new continuation conditions: "External
block relaying"
•
Completion of position tracking for absolute encoder (load
gear)
•
Jerk limitation
•
"Set reference point" also with intermediate stop (Traversing
blocks and MDI)
•
Reversing cam functionality also with reference run without
reference cam
x
x
-
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......