Servo control
4.5 Torque setpoint limitation
Drive functions
98
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
4.5
Torque setpoint limitation
The steps required for limiting the torque setpoint are as follows:
●
Define the torque setpoint and an additional torque setpoint
●
Generate torque limits
The torque setpoint can be limited to a maximum permissible value in all four quadrants.
Different limits can be parameterized for motor and regenerative modes.
Figure 4-7
Current/torque setpoint limiting
Note
This function is always active with the preset factory settings.
Properties
The connector inputs of the function are initialized with fixed torque limits. If required, the
torque limits can also be defined dynamically (during operation).
●
A control bit can be used to select the torque limitation mode. The following alternatives
are available:
–
Upper and lower torque limit
–
Motor and regenerative torque limit
●
Additional power limitation configurable
–
Motor mode power limit
–
Regenerative mode power limit
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......