Basic information about the drive system
13.11 DRIVE-CLiQ
Drive functions
1002
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Note
Autonomous (emergency) operation is possible only for Motor Modules and Basic Line
Modules with article numbers that end with the code ..3, e.g. 6SL3130-6TE21-6AA3.
Principle of operation
Two task profiles are obtained for autonomous operation:
●
Recognize that a component is getting into a critical state and the protective function
must be maintained.
●
Restore communication with the higher-level controller.
In order to maintain the protective function, the time-slice system must remain active.
The logged-on time-slice system remains active until the protective functions signal that a
safe state has been reached and the time slices can therefore be deactivated. When
restarting the communication, if the DRIVE-CLiQ master signals that no bus timing changes
have been made with respect to the old parameterization, then synchronization is possible.
The time-slice system remains the same as before.
Note
All algorithms for autonomous operation are executed as a background process for the
component. They thus have no influence on the computer resources utilized cyclically by the
component.
Communication restart includes a topology detection during emergency operation.
Note
When the component is running in emergency mode, it cannot be deactivated.
Preparation for autonomous time-slice operation
The application signals (basic system DRIVE-CLiQ slave components) preparation for
autonomous time-slice operation. This occurs, for example, when the "armature short-circuit"
protective function is active or in chopper operation.
Changeover from normal to autonomous operation
The application activates autonomous time-slice operation. Changeover takes place
instantaneously.
Changeover from autonomous to normal operation
It is always possible to change over into normal operation without a POWER ON.
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......