Basic functions
7.2 Reference parameters/scaling
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
317
Scaling for the SERVO drive object
Table 7- 2
Scaling for the SERVO drive object
Size
Scaling parameter
Default when commissioning for the first time
Reference speed
100% = p2000
Induction motor p2000 = Maximum motor
speed (p0322)
Synchronous motor p2000 = Rated motor
speed (p0311)
Reference voltage
100% = p2001
p2001 = 1000 V
Reference current
100% = p2002
p2002 = Motor limit current (p0338); when
p0338 = "0", 2 · rated motor current (p0305)
Reference torque
100% = p2003
p2003 = p0338 · p0334; when "0", 2 · rated
motor torque (p0333)
Reference power
100% = r2004
r2004 = p2003 · p2000 · π / 30
Reference angle
100% = p2005
90°
Reference acceleration 100% = p2007
0.01 1/s
2
Reference frequency
100% = p2000/60
-
Reference modulation
depth
100% = Maximum output
voltage without overload
-
Reference flux
100% = Rated motor flux
-
Reference temperature 100 % = p2006
100°C
Reference electrical
angle
100 % = p2005
90°
Note
Operation of motors in the field-weakening range
If the motors are to be operated in the field-weakening range > 2:1, the value of parameter
p2
000 must be set ≤ 1/2 x maximum speed of the drive object.
Scaling for the A_INF drive object
Table 7- 3
Scaling for the A_INF drive object
Size
Scaling parameter
Default when commissioning for the first time
Reference frequency
100% = p2000
p2000 = p0211
Reference voltage
100% = p2001
p2001 = p0210
Reference current
100% = p2002
p2002 = r0206/p0210/√3
Reference power
100% = r2004
r2004 = r0206
Reference modulation
depth
100% = Maximum output
voltage without overload
-
Reference temperature 100 % = p2006
100°C
Reference electrical
angle
100 % = p2005
90°
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......