Function modules
8.7 Position control
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
503
Following error monitoring is activated via p2546 (following error tolerance). If the absolute
value of the dynamic following error (r2563) is greater than p2546, fault F07452 is output and
bit r2648.8 is reset.
Figure 8-12 Cam controllers
The position controller has two cam controllers. If cam position p2547 or p2548 is passed in
the positive direction (r2521 > p2547 or p2548), then cam signals r2683.8 and r2683.9 are
reset.
Features
●
Standstill monitoring (p2542, p2543)
●
Positioning monitoring (p2544, p2545)
●
Dynamic following error monitoring (p2546, r2563)
●
Cam controllers (p2547, p2548, p2683.8, p2683.9)
Function diagrams (see SINAMICS S120/S150 List Manual)
•
4020
Position control - Standstill monitoring / positioning monitoring (r0108.3 = 1)
•
4025
Position control - Dynamic following error monitoring, cam controllers
(r0108.3 = 1)
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......