7–6 • Keying
Synergy 100 MD Operator’s Manual (v7.2 MD-S100)
With
Auto Select
Keys, two signals are used to cut and fill the hole. There is a Key
(alpha) signal and a fill (video) signal. These signals originate from devices such as
character generators, still stores, DVEs, or graphics systems.
When you choose an
Auto Select Key
and press a Key source (on the
Key Bus
), the
switcher
automatically
selects both the alpha and fill signals. These signals were
linked
together during the installation procedure. Refer to Chapter 7 “
BNC
Configuration and Check
” of the
Synergy 100 MD Engineering Manual
for
information on assigning a Key alpha to a video input.
In addition to these buttons, there are two buttons used as hotkeys for your favorite Auto
Select Keys originating from character generators, still stores, DVEs, or another desired
source.
•
Press
CHAR GEN1
to select your most frequently used
Auto Select
Key, without
having to hunt for it on the
Key Bus
. When pressed, the Key type and Key source
are automatically selected,
KEY MEM
is turned
On
and Key modifiers are turned
Off
to provide a
clean
CG Key. Refer to the section “
” on page 7-40 for more information.
•
Press
CHAR GEN2
to choose an alternate frequently used
Auto Select
Key. This
button works in the same manner as
CHAR GEN1
.
2. Key Modifier Section
The buttons and knobs in the
Key Modifier Section
allow you to modify the Key that is
currently selected.
•
Press
KEY INVERT
to invert the polarity of the selected Key signal. For example,
if a Self Key source has white letters on a black background, the white letters
normally cut the hole. When
KEY INVERT
is pressed, the polarity of the signal is
reversed and the
black background
cuts the hole. This function is often used to Key
black text that is printed on a white background.
•
The
KEY MEM
(memory) function applies to
Auto Select
Keys only. This function
allows you to store and recall
one set
of clip and gain settings
per crosspoint
.
The
KEY MEM
button turns on
automatically
when you press
AUTO SELECT
and choose an Auto Select Key source on the
Key Bus
. This function recalls the
settings for the Key from memory. With the button lit, clip and gain settings are
locked. If you toggle the
KEY MEM
button
Off
, the clip and gain setting will be
unlocked
, allowing you to make temporary adjustments to the settings of the linear
Key. Toggling the button back
On
will
restore
the default settings for the Key
source from memory.
Although the default clip and gain settings were set during the switcher installation
process, you can also use the
KEY MEM
button to store
new
default values for the
selected linear Key source. Refer to the section “
on page 7-10 for more information.
•
Press
MASK
to activate the
Mask
controls. These controls allow you to selectively
eliminate unwanted portions of a Key signal, similar to the “crop” function found
on many DVEs. Using an adjustable box pattern, you can size and position the mask
to hide the top, bottom, left or right edges of the Key.
Note
All Key types can be inverted, except for
Squeeze & Tease MD
boxes.
CHAR
GEN1
CHAR
GEN2
KEY
INVERT
KEY
MEM
MASK
Содержание Synergy 100 MD
Страница 1: ...Ross Video Limited Operator s Manual Software Issue 7 2 MD S100...
Страница 10: ......
Страница 50: ...2 10 Control Panel Introduction Synergy 100 MD Operator s Manual v7 2 MD S100...
Страница 62: ...3 12 Using the Menu System Synergy 100 MD Operator s Manual v7 2 MD S100...
Страница 80: ...4 18 Switcher Basics Synergy 100 MD Operator s Manual v7 2 MD S100...
Страница 148: ...7 42 Keying Synergy 100 MD Operator s Manual v7 2 MD S100...
Страница 182: ...10 12 Peripheral Control and More Synergy 100 MD Operator s Manual v7 2 MD S100...
Страница 210: ...11 28 Global Store Synergy 100 MD Operator s Manual v7 2 MD S100...
Страница 238: ...12 28 Squeeze Tease MD Basic Operation Synergy 100 MD Operator s Manual v7 2 MD S100...
Страница 256: ...14 6 Advanced Positioning Synergy 100 MD Operator s Manual v7 2 MD S100...
Страница 276: ...16 8 Preprocessor Effects Synergy 100 MD Operator s Manual v7 2 MD S100...
Страница 316: ...17 40 Squeeze Tease MD Sequences and Wipes Synergy 100 MD Operator s Manual v7 2 MD S100...
Страница 376: ...21 4 Appendix B Synergy Effects Synergy 100 MD Operator s Manual v7 2 MD S100...
Страница 382: ...22 6 Appendix C Hotkeys Synergy 100 MD Operator s Manual v7 2 MD S100...
Страница 386: ...GL 4 Glossary of Terms Synergy 100 MD Operator s Manual v7 2 MD S100...
Страница 402: ...IX 16 Index Synergy 100 MD Operator s Manual v7 2 MD S100...