269
269
9) Crush the tablet with a clean stirrer until it is completely dissolved.
10) Add a "Ammonia N° 2 Photometer" tablet to the water sample in the
cuvette.
11) Crush the tablet with a clean stirrer until it is completely dissolved.
12) Replace the lid on the cuvette, swivel it carefully and insert it in the
sampling chamber of the PrimeLab. Align the arrow on the front of the
cuvette. Press TEST.
13) After the lapse of a 10 minute countdown the determined result is
displayed. Press button 4 to save the test result together with date and
time on the device.
4
4
!
Possible messages in the line below the measurement value:
"low! / high! / good!":
Assessment of the measurement value relative to the ideal range defined by you.
"Overrange! / underrange!":
Measurement value for this parameter is outside the value range of this method.
0.1 - 2.5 mg/l
((NH ) CO)
2 2
(120)
Urea
Name on device: 120-Urea-tab-liq
Liquid
+Liquid
Tablet
Note(s)
-> Ammonia N° 1 tablet only dissolves entirely after Ammonia N° 2 tablet
was added.
-> Samples with concentrations above 2 mg/l Urea may lead to results in
between the measurement range. If so, please dilute sample with Urea
free water and re-do the test.
-> Ammonia and chloramines will be detected together. The result displayed
will show the sum of both.
-> Temperature of the sample needs to be between 20°C and 30°C.
-> Test needs to be carried out not later than 1 hour after taking the sample.
-> If sea water is tested, sample needs to be pre-treated with special
conditioning powder before Ammonia N° 1 Photometer tablet is added.
-> Do not store PL Urea 1 below 10°C as it might granulate.
-> PL Urea 2 needs to be stored between 4°C and 8°C.
Continued...
Содержание 1.0 MULTITEST
Страница 1: ......
Страница 21: ...Menu MEM Memory left open for technical reasons MEM 5 MEM 5 ...
Страница 23: ...INFO 2 INFO 2 Menu INFO left open for technical reasons ...
Страница 33: ...left open for technical reasons ...
Страница 276: ...243 243 Tablet Note s Conversion to Na SO 2 3 Continued Name on device 53 Sulphite LR tab 53 Sulphite LR 0 5 mg l SO 3 ...
Страница 323: ...PrimeLab Desktop Assistant PDA 9 PDA 9 left open for technical reasons ...
Страница 333: ...PrimeLab Desktop Assistant PDA 19 PDA 19 left open for technical reasons ...
Страница 340: ...PrimeLab Desktop Assistant Menu Account data Print test results report PDA 26 PDA 26 ...
Страница 342: ...PrimeLab Desktop Assistant Menu Account data Generate dosage recommendations PDA 28 PDA 28 ...
Страница 343: ...Page empty for technical reasons PrimeLab Desktop Assistant PDA 29 PDA 29 ...
Страница 347: ...Page empty for technical reasons PrimeLab Desktop Assistant PDA 33 PDA 33 ...