Appendix Function Parameter List
267
P157
The 2
nd
Analog Superimposed Value
Bias value can be superimposed to the 2
nd
analog input value with this
parameter.
Name
Setting range
The 2
nd
Analog
Superimposed
Value
-
100.0% to
+
100.0%
Related parameters: P124, P126 to P127
·
For setting method, please refer to “P124: The 2
nd
Analog Input Function
Select”.
P158
The 2
nd
Motor Capacity
・
During vector control or when auto torque boost or slip compensation is
performed through V/F control, inverter capacity used to drive the motor can
be set.
·
Related setting values are the same as the those of 1
st
motor. Please refer to
parameter “P130: Motor Capacity”.
·
If data is changed, the setting values of parameter “P160: The 2
nd
Voltage
Compensation Constant” and “P161: The 2
nd
Slip Compensation Frequency”
will be automatically changed to motor constants recommended by our
company.
P159
The 2
nd
Motor Pole Number
・
During vector control or when auto torque boost or slip compensation is
performed through V/F control, pole number required to drive the motor can
be set.
·
Related setting values are the same as the those of 1
st
motor. Please refer to
parameter “P131: Motor Pole Number”.
Содержание VF200
Страница 1: ...VF200 WME VF200 A 2013 01 panasonic net id pidsx global ...
Страница 2: ......
Страница 7: ......
Страница 8: ...1 Safety Precautions ...
Страница 14: ...Safety Precautions 7 7 Warning Label on Inverter VF200 ...
Страница 15: ...Safety Precautions 8 ...
Страница 16: ...9 Points for Handling Special Precautions 10 ...
Страница 19: ...Points for Handling ...
Страница 20: ...13 1 Parts Identification 1 1 Part Names and Functions 14 1 2 Details on Part Number 16 ...
Страница 29: ...2 Installation 22 VF200 ...
Страница 49: ...42 ...
Страница 56: ...4 Operation Method Basic Operation ...
Страница 66: ...4 Operation Method Basic Operation 7 Stop operation Press button The motor starts to decelerate till to stop ...
Страница 75: ...4 Operation Method Basic Operation ...
Страница 76: ...69 5 Control Status Monitor 5 1 List of Control Status Monitor Items 70 5 2 Introduction of Monitor No 72 ...
Страница 88: ...81 6 Function Parameters 6 1 Setting and Changing Function Parameters 8 6 2 Function Parameter List 83 ...
Страница 101: ...6 Function Parameters 94 ...
Страница 102: ...95 7 Custom Mode 7 1 Allocating Parameter No 96 7 2 Setting and Changing Parameters 98 ...
Страница 107: ...7 Custom Mode 100 ...
Страница 119: ...8 Setting Mode and Copy Function of Built in Memory 112 ...
Страница 126: ...9 Troubleshooting 119 9 3 3 Breaker Trip 9 3 4 Motor Overheating 9 3 5 Communication Failed ...
Страница 127: ...9 Troubleshooting 120 ...
Страница 136: ...129 11 Specifications 11 1 Rated Specifications 130 11 2 Standard Specifications 132 11 3 Common Specifications 133 ...
Страница 145: ...11 Specifications 138 ...
Страница 146: ...139 Appendix Function Parameter List ...
Страница 208: ...Appendix Function Parameter List 201 ...