Appendix Function Parameter List
1
59
・
Overcurrent trip prevention function is activated regardless of setting of
parameter “P018: Overcurrent Stall Prevention Function” after parameter
“P020: Current Limit Function” is set.
Related parameter: P021
P019
Overvoltage Stall Prevention Function
During deceleration, when the deceleration time is too short for the inertial
load, this parameter can be used to temporarily retard deleceration, thus
preventing overvoltage trip.
Setting value
Details
0
Stall prevention function disabled
1
Stall prevention function enabled
・
When regenerative brake is used in the inverter with braking function, please
set the value to “0”.
(The regenerative brake function will not operate since the factory setting is
“1”).
・
The specifications of built-in brake of inverter are as follows. Please take
them into full consideration before using.
Please note that the braking resistor and inverter could be damaged if used
beyond specifications.
(1) Braking torque:100%
(2) Maximum duty factor (%ED): 5%
(3) Maximum working time: 5 s
・
Only brake circuit is built in the inverter.
Содержание VF200
Страница 1: ...VF200 WME VF200 A 2013 01 panasonic net id pidsx global ...
Страница 2: ......
Страница 7: ......
Страница 8: ...1 Safety Precautions ...
Страница 14: ...Safety Precautions 7 7 Warning Label on Inverter VF200 ...
Страница 15: ...Safety Precautions 8 ...
Страница 16: ...9 Points for Handling Special Precautions 10 ...
Страница 19: ...Points for Handling ...
Страница 20: ...13 1 Parts Identification 1 1 Part Names and Functions 14 1 2 Details on Part Number 16 ...
Страница 29: ...2 Installation 22 VF200 ...
Страница 49: ...42 ...
Страница 56: ...4 Operation Method Basic Operation ...
Страница 66: ...4 Operation Method Basic Operation 7 Stop operation Press button The motor starts to decelerate till to stop ...
Страница 75: ...4 Operation Method Basic Operation ...
Страница 76: ...69 5 Control Status Monitor 5 1 List of Control Status Monitor Items 70 5 2 Introduction of Monitor No 72 ...
Страница 88: ...81 6 Function Parameters 6 1 Setting and Changing Function Parameters 8 6 2 Function Parameter List 83 ...
Страница 101: ...6 Function Parameters 94 ...
Страница 102: ...95 7 Custom Mode 7 1 Allocating Parameter No 96 7 2 Setting and Changing Parameters 98 ...
Страница 107: ...7 Custom Mode 100 ...
Страница 119: ...8 Setting Mode and Copy Function of Built in Memory 112 ...
Страница 126: ...9 Troubleshooting 119 9 3 3 Breaker Trip 9 3 4 Motor Overheating 9 3 5 Communication Failed ...
Страница 127: ...9 Troubleshooting 120 ...
Страница 136: ...129 11 Specifications 11 1 Rated Specifications 130 11 2 Standard Specifications 132 11 3 Common Specifications 133 ...
Страница 145: ...11 Specifications 138 ...
Страница 146: ...139 Appendix Function Parameter List ...
Страница 208: ...Appendix Function Parameter List 201 ...