3. Setting value (SP)
・
Setting signal of setting value (SP) is set with
parameter P004 (Frequency Setting Signal).
(Note) When Parameter P004 = “1” or “7”,
setting value (SP) is set with parameter P111
(PID Targert Value).
・
The relationship between setting signal and
setting value (SP) is set with parameter P102
to P104 (Bias/Gain Function Select, Bias
Frequency and Gain Frequency Setting).
<Example> 0 V = 0%, 5 V = 100%
4. PID operation mode select
・
PID operation mode is selected with parameter P106 (PID Control Mode).
5. Proportional gain (Kp), integral time (Ti), derivative time (Td) and control
cycle (Ts) settings
・
Coefficients (Kp, Ti and Td) used in PID control are set with parameter
P107 to P109.
* Automatic tuning function can be used to adjust coefficients (Kp, Ti and
Td) and change setting values.
・
PID control cycle (Ts) is set with parameter P110.
*The lower/upper limit of output frequency is set with parameter P099 and
P100.
Содержание VF200
Страница 1: ...VF200 WME VF200 A 2013 01 panasonic net id pidsx global ...
Страница 2: ......
Страница 7: ......
Страница 8: ...1 Safety Precautions ...
Страница 14: ...Safety Precautions 7 7 Warning Label on Inverter VF200 ...
Страница 15: ...Safety Precautions 8 ...
Страница 16: ...9 Points for Handling Special Precautions 10 ...
Страница 19: ...Points for Handling ...
Страница 20: ...13 1 Parts Identification 1 1 Part Names and Functions 14 1 2 Details on Part Number 16 ...
Страница 29: ...2 Installation 22 VF200 ...
Страница 49: ...42 ...
Страница 56: ...4 Operation Method Basic Operation ...
Страница 66: ...4 Operation Method Basic Operation 7 Stop operation Press button The motor starts to decelerate till to stop ...
Страница 75: ...4 Operation Method Basic Operation ...
Страница 76: ...69 5 Control Status Monitor 5 1 List of Control Status Monitor Items 70 5 2 Introduction of Monitor No 72 ...
Страница 88: ...81 6 Function Parameters 6 1 Setting and Changing Function Parameters 8 6 2 Function Parameter List 83 ...
Страница 101: ...6 Function Parameters 94 ...
Страница 102: ...95 7 Custom Mode 7 1 Allocating Parameter No 96 7 2 Setting and Changing Parameters 98 ...
Страница 107: ...7 Custom Mode 100 ...
Страница 119: ...8 Setting Mode and Copy Function of Built in Memory 112 ...
Страница 126: ...9 Troubleshooting 119 9 3 3 Breaker Trip 9 3 4 Motor Overheating 9 3 5 Communication Failed ...
Страница 127: ...9 Troubleshooting 120 ...
Страница 136: ...129 11 Specifications 11 1 Rated Specifications 130 11 2 Standard Specifications 132 11 3 Common Specifications 133 ...
Страница 145: ...11 Specifications 138 ...
Страница 146: ...139 Appendix Function Parameter List ...
Страница 208: ...Appendix Function Parameter List 201 ...