5. Control Status Monitor
7
4
n009
n010
Control Circuit Terminal Status (Input Signal)
Control Circuit Terminal Status (Output Signal)
For displaying various status of input and output signals of control circuit
terminals.
When input terminals (
②
to
⑧
) and common terminal (
①
or
⑨
) are turned
ON, segment a1 to g1 light up; when input terminals (
②
to
⑧
) and common
terminal (
①
or
⑨
) are turned OFF, segment a1 to g1 light out.
When output terminals are closed (ON) between
⑩
to
⑫
and
⑪
to
⑫
,
segment a1 and b1 of n010 light up; when output terminals are opened (OFF)
between
⑩
to
⑫
and
⑪
to
⑫
, segment a1 and b1 of n010 light out.
Segment c1 lights up when the output terminal is ON (Excitation in ON status:
short circuit across A-C; non-excitation in ON status: short circuit across B-C);
segment c1 lights out when the output terminal is OFF (Excitation in ON status:
open circuit across B-C; non-excitation in ON status: open circuit across A-C).
LED segment indication
Monitor No.
I/O signal
Terminal
indication
Signal ON
Signal OFF
Run/stop
“a” lights up
“a1” lights up
“a1” lights out
Forward/reverse run
“b” lights up
“b1” lights up
“b1” lights out
SW1
“c” lights up
“c1” lights up
“c1” lights out
SW2
“d” lights up
“d1” lights up
“d1” lights out
SW3
“e” lights up
“e1” lights up
“e1” lights out
SW4
“f” lights up
“f1” lights up
“f1” lights out
n009
SW5
“g” lights up
“g1” lights up
“g1” lights out
Open-collector 1
“a” lights up
“a1” lights up
“a1” lights out
Open-collector 2
“b” lights up
“b1” lights up
“b1” lights out
n010
Relay
“c” lights up
“c1” lights up
“c1” lights out
Содержание VF200
Страница 1: ...VF200 WME VF200 A 2013 01 panasonic net id pidsx global ...
Страница 2: ......
Страница 7: ......
Страница 8: ...1 Safety Precautions ...
Страница 14: ...Safety Precautions 7 7 Warning Label on Inverter VF200 ...
Страница 15: ...Safety Precautions 8 ...
Страница 16: ...9 Points for Handling Special Precautions 10 ...
Страница 19: ...Points for Handling ...
Страница 20: ...13 1 Parts Identification 1 1 Part Names and Functions 14 1 2 Details on Part Number 16 ...
Страница 29: ...2 Installation 22 VF200 ...
Страница 49: ...42 ...
Страница 56: ...4 Operation Method Basic Operation ...
Страница 66: ...4 Operation Method Basic Operation 7 Stop operation Press button The motor starts to decelerate till to stop ...
Страница 75: ...4 Operation Method Basic Operation ...
Страница 76: ...69 5 Control Status Monitor 5 1 List of Control Status Monitor Items 70 5 2 Introduction of Monitor No 72 ...
Страница 88: ...81 6 Function Parameters 6 1 Setting and Changing Function Parameters 8 6 2 Function Parameter List 83 ...
Страница 101: ...6 Function Parameters 94 ...
Страница 102: ...95 7 Custom Mode 7 1 Allocating Parameter No 96 7 2 Setting and Changing Parameters 98 ...
Страница 107: ...7 Custom Mode 100 ...
Страница 119: ...8 Setting Mode and Copy Function of Built in Memory 112 ...
Страница 126: ...9 Troubleshooting 119 9 3 3 Breaker Trip 9 3 4 Motor Overheating 9 3 5 Communication Failed ...
Страница 127: ...9 Troubleshooting 120 ...
Страница 136: ...129 11 Specifications 11 1 Rated Specifications 130 11 2 Standard Specifications 132 11 3 Common Specifications 133 ...
Страница 145: ...11 Specifications 138 ...
Страница 146: ...139 Appendix Function Parameter List ...
Страница 208: ...Appendix Function Parameter List 201 ...