Appendix Function Parameter List
16
7
P026
Waiting Time
Waiting time required by the start mode, the ride-through restart and retry
function can be set.
Data setting range (s) 0.1 to 100.0
Related parameters: P022 to P025
P027
Reverse Run Lock
When used only in forward run mode, reverse run can be disabled to avoid
possible mishandling.
Setting value
Details
0
Reverse run operation enabled
(Both forward run and reverse run
operation enabled)
1
Reverse run disabled
(Only forward run operation enabled)
・
When disabled, reverse run cannot be performed during the operation of
panel, external control and communication.
Related parameter: P004
P028
Stop Mode
Ramp-to-stop or coast-to-stop mode can be selected when stopping the
inverter.
Setting value
Mode
Details
0
Ramp-to-stop
The inverter is stopped by the stop signal
depending on the frequency decreased according
to the deceleration time.
1
Coast-to-stop
The inverter output is shut off immediately by the
stop signal.
Содержание VF200
Страница 1: ...VF200 WME VF200 A 2013 01 panasonic net id pidsx global ...
Страница 2: ......
Страница 7: ......
Страница 8: ...1 Safety Precautions ...
Страница 14: ...Safety Precautions 7 7 Warning Label on Inverter VF200 ...
Страница 15: ...Safety Precautions 8 ...
Страница 16: ...9 Points for Handling Special Precautions 10 ...
Страница 19: ...Points for Handling ...
Страница 20: ...13 1 Parts Identification 1 1 Part Names and Functions 14 1 2 Details on Part Number 16 ...
Страница 29: ...2 Installation 22 VF200 ...
Страница 49: ...42 ...
Страница 56: ...4 Operation Method Basic Operation ...
Страница 66: ...4 Operation Method Basic Operation 7 Stop operation Press button The motor starts to decelerate till to stop ...
Страница 75: ...4 Operation Method Basic Operation ...
Страница 76: ...69 5 Control Status Monitor 5 1 List of Control Status Monitor Items 70 5 2 Introduction of Monitor No 72 ...
Страница 88: ...81 6 Function Parameters 6 1 Setting and Changing Function Parameters 8 6 2 Function Parameter List 83 ...
Страница 101: ...6 Function Parameters 94 ...
Страница 102: ...95 7 Custom Mode 7 1 Allocating Parameter No 96 7 2 Setting and Changing Parameters 98 ...
Страница 107: ...7 Custom Mode 100 ...
Страница 119: ...8 Setting Mode and Copy Function of Built in Memory 112 ...
Страница 126: ...9 Troubleshooting 119 9 3 3 Breaker Trip 9 3 4 Motor Overheating 9 3 5 Communication Failed ...
Страница 127: ...9 Troubleshooting 120 ...
Страница 136: ...129 11 Specifications 11 1 Rated Specifications 130 11 2 Standard Specifications 132 11 3 Common Specifications 133 ...
Страница 145: ...11 Specifications 138 ...
Страница 146: ...139 Appendix Function Parameter List ...
Страница 208: ...Appendix Function Parameter List 201 ...