Appendix Function Parameter List
233
P118
P119
The 2
nd
Electronic Thermal Select
The 2
nd
Thermal Current Setting
Electronic thermal operation level can be selected and set with the 2
nd
characteristics select button when the inverter output is stopped. Operation
coasts to stop when OL is displayed.
■
Example for setting current and thermal operation (P016 = 1)
・
Setting current
×
100
%
⇒
Does not operate
・
Setting current
×
125
%
⇒
Operate (OL trip)
■
Parameter P118: The 2
nd
Electronic Thermal Select
Setting
value
Validity of
function
Details of function
0
×
OL trip will occur if current up to 140% of inverter’s rating
continues for 1 minute.
1
○
Without output frequency derating
2
○
With output frequency derating
3
○
Forced air-cooled motor specification
*About frequency derating
Cooling performance of the motor will be reduced at lower speed. To handle
the problem, this function can automatically compensate operation level.
Содержание VF200
Страница 1: ...VF200 WME VF200 A 2013 01 panasonic net id pidsx global ...
Страница 2: ......
Страница 7: ......
Страница 8: ...1 Safety Precautions ...
Страница 14: ...Safety Precautions 7 7 Warning Label on Inverter VF200 ...
Страница 15: ...Safety Precautions 8 ...
Страница 16: ...9 Points for Handling Special Precautions 10 ...
Страница 19: ...Points for Handling ...
Страница 20: ...13 1 Parts Identification 1 1 Part Names and Functions 14 1 2 Details on Part Number 16 ...
Страница 29: ...2 Installation 22 VF200 ...
Страница 49: ...42 ...
Страница 56: ...4 Operation Method Basic Operation ...
Страница 66: ...4 Operation Method Basic Operation 7 Stop operation Press button The motor starts to decelerate till to stop ...
Страница 75: ...4 Operation Method Basic Operation ...
Страница 76: ...69 5 Control Status Monitor 5 1 List of Control Status Monitor Items 70 5 2 Introduction of Monitor No 72 ...
Страница 88: ...81 6 Function Parameters 6 1 Setting and Changing Function Parameters 8 6 2 Function Parameter List 83 ...
Страница 101: ...6 Function Parameters 94 ...
Страница 102: ...95 7 Custom Mode 7 1 Allocating Parameter No 96 7 2 Setting and Changing Parameters 98 ...
Страница 107: ...7 Custom Mode 100 ...
Страница 119: ...8 Setting Mode and Copy Function of Built in Memory 112 ...
Страница 126: ...9 Troubleshooting 119 9 3 3 Breaker Trip 9 3 4 Motor Overheating 9 3 5 Communication Failed ...
Страница 127: ...9 Troubleshooting 120 ...
Страница 136: ...129 11 Specifications 11 1 Rated Specifications 130 11 2 Standard Specifications 132 11 3 Common Specifications 133 ...
Страница 145: ...11 Specifications 138 ...
Страница 146: ...139 Appendix Function Parameter List ...
Страница 208: ...Appendix Function Parameter List 201 ...