11. Specifications
13
3
11.3 Common Specifications
Items
Specifications
Frequency range
0.5 to 400 Hz
Frequency display
Digital display
Frequency accuracy
Analog setting: within ±0.5% of maximum setting
frequency (25°C±10°C)
Digital setting: within ±0.01% of maximum setting
frequency (-10°C to +50°C)
Output
Frequency
Frequency resolution
Digital setting: 0.1 Hz
Analog setting: 0.1 Hz (in 50/60 Hz mode)
Inverter control mode
High carrier frequency sinusoidal PWM control
(V/F control or simple vector control is available.)
Carrier frequency
•
V/F control setting: 7 options can be selected
(adjustable from 0.8 to 10 kHz).
(0.8, 1.1, 1.6, 2.5, 5.0, 7.5, 10.0 kHz)
•
Simple vector control setting: 4 options can be
selected (adjustable from 2.5 to 10 kHz).
Start/Stop
•
Operation panel buttons
•
1a contact signal and 3-wire input (1a and 1b
contact signals) can be selected.
•
RS485 communication
•
Wait time (0.1 to 100 s) can be set.
Forward/Reverse run
•
Operation panel buttons
•
1a contact signal (reverse run can be disabled.)
•
RS485 communication
JOG operation
Operation frequency: adjustable from 0.5 to 400 Hz
Acceleration/deceleration time: adjustable from
0.04 to 3600 s
Stop mode
Ramp-to-stop / coast-to-stop (switchable)
Reset function
Stop signal reset/external reset/panel reset
(optional) / power supply reset
Start frequency
Adjustable from 0.5 to 60 Hz
Operation
Stop frequency
Adjustable from 0.5 to 60 Hz
Содержание VF200
Страница 1: ...VF200 WME VF200 A 2013 01 panasonic net id pidsx global ...
Страница 2: ......
Страница 7: ......
Страница 8: ...1 Safety Precautions ...
Страница 14: ...Safety Precautions 7 7 Warning Label on Inverter VF200 ...
Страница 15: ...Safety Precautions 8 ...
Страница 16: ...9 Points for Handling Special Precautions 10 ...
Страница 19: ...Points for Handling ...
Страница 20: ...13 1 Parts Identification 1 1 Part Names and Functions 14 1 2 Details on Part Number 16 ...
Страница 29: ...2 Installation 22 VF200 ...
Страница 49: ...42 ...
Страница 56: ...4 Operation Method Basic Operation ...
Страница 66: ...4 Operation Method Basic Operation 7 Stop operation Press button The motor starts to decelerate till to stop ...
Страница 75: ...4 Operation Method Basic Operation ...
Страница 76: ...69 5 Control Status Monitor 5 1 List of Control Status Monitor Items 70 5 2 Introduction of Monitor No 72 ...
Страница 88: ...81 6 Function Parameters 6 1 Setting and Changing Function Parameters 8 6 2 Function Parameter List 83 ...
Страница 101: ...6 Function Parameters 94 ...
Страница 102: ...95 7 Custom Mode 7 1 Allocating Parameter No 96 7 2 Setting and Changing Parameters 98 ...
Страница 107: ...7 Custom Mode 100 ...
Страница 119: ...8 Setting Mode and Copy Function of Built in Memory 112 ...
Страница 126: ...9 Troubleshooting 119 9 3 3 Breaker Trip 9 3 4 Motor Overheating 9 3 5 Communication Failed ...
Страница 127: ...9 Troubleshooting 120 ...
Страница 136: ...129 11 Specifications 11 1 Rated Specifications 130 11 2 Standard Specifications 132 11 3 Common Specifications 133 ...
Страница 145: ...11 Specifications 138 ...
Страница 146: ...139 Appendix Function Parameter List ...
Страница 208: ...Appendix Function Parameter List 201 ...