Points for Handling
10
Special Precautions
Use the inverter only within allowable ambient temperature range
(-10
~
50°C).
Since service life of the inverter is greatly affected by ambient temperature, use
it within allowable temperature range. Also, observe the installation directions
and conditions. (Refer to P.21)
The inverter will be damaged if the power voltage is applied to its
output side.
Applying power voltage to the output terminal U, V or W will damage the
inverter. Check carefully for faulty wiring and operation sequence (commercial
switching circuit, etc.). Never apply a voltage exceeding the allowable range.
Never touch inside of the inverter during operation.
Failure to do so could be extremely dangerous, since the inverter contains
high-voltage circuit. Before making an internal check, be sure to wait at least 5
minutes after turning OFF the inverter. Do not touch heat sink or braking
resistor during operation as these parts are under high temperature.
Radio interference
The main circuit of the inverter contains a high-frequency harmonic component
and may interfere with communicating equipments (such as AM radio) nearby.
The severity of interference depends on the radio field strength and is hard to
be eliminated completely. While it may be reduced by relocating radio antenna,
using noise filter, housing the inverter in a metal box, or routing cables in
conduit. (Please inquire separately.)
Do not conduct insulation test between wires of the inverter.
To measure insulation resistance between power cord and motor wires, please
remove the cables connected to the inverter and conduct test with them. Do not
conduct insulation test on the control circuits. However, insulation test can be
performed between charging unit and the ground.
Содержание VF200
Страница 1: ...VF200 WME VF200 A 2013 01 panasonic net id pidsx global ...
Страница 2: ......
Страница 7: ......
Страница 8: ...1 Safety Precautions ...
Страница 14: ...Safety Precautions 7 7 Warning Label on Inverter VF200 ...
Страница 15: ...Safety Precautions 8 ...
Страница 16: ...9 Points for Handling Special Precautions 10 ...
Страница 19: ...Points for Handling ...
Страница 20: ...13 1 Parts Identification 1 1 Part Names and Functions 14 1 2 Details on Part Number 16 ...
Страница 29: ...2 Installation 22 VF200 ...
Страница 49: ...42 ...
Страница 56: ...4 Operation Method Basic Operation ...
Страница 66: ...4 Operation Method Basic Operation 7 Stop operation Press button The motor starts to decelerate till to stop ...
Страница 75: ...4 Operation Method Basic Operation ...
Страница 76: ...69 5 Control Status Monitor 5 1 List of Control Status Monitor Items 70 5 2 Introduction of Monitor No 72 ...
Страница 88: ...81 6 Function Parameters 6 1 Setting and Changing Function Parameters 8 6 2 Function Parameter List 83 ...
Страница 101: ...6 Function Parameters 94 ...
Страница 102: ...95 7 Custom Mode 7 1 Allocating Parameter No 96 7 2 Setting and Changing Parameters 98 ...
Страница 107: ...7 Custom Mode 100 ...
Страница 119: ...8 Setting Mode and Copy Function of Built in Memory 112 ...
Страница 126: ...9 Troubleshooting 119 9 3 3 Breaker Trip 9 3 4 Motor Overheating 9 3 5 Communication Failed ...
Страница 127: ...9 Troubleshooting 120 ...
Страница 136: ...129 11 Specifications 11 1 Rated Specifications 130 11 2 Standard Specifications 132 11 3 Common Specifications 133 ...
Страница 145: ...11 Specifications 138 ...
Страница 146: ...139 Appendix Function Parameter List ...
Страница 208: ...Appendix Function Parameter List 201 ...