Appendix Function Parameter List
239
■
Auxiliary frequency setting signal (setting value = “3”)
・
The 2
nd
analog input terminal can be used as auxiliary frequency setting
signal.
・
Input signals (0 to 5 V, 0 to 10 V, 4 to 20 mA and 0 to 20 mA) are fed back as
auxiliary frequency setting signal added to the 1
st
frequency setting signal (%)
(setting example: -10% to +10%).
・
The setting value of auxiliary frequency setting signal is converted inside the
inverter with parameter “P126: The 2
nd
Bias Frequency Setting”, “P127: The
2
nd
Gain Frequency Setting” and “P157: The 2
nd
Analog Superimposed Value
Setting”.
<Example> When the analog input ranges from 0 to 5 V and both the 2
nd
bias
value and the 2
nd
gain are set to “10”
・
It can be used when the result of PID calculation made by external devices
such as PLC is added to the speed command value.
・
The inverter’s output frequency is determined by the following formula.
Output frequency = Max. output frequency
×
(The 1
st
frequency setting signal
(%) + auxiliary frequency setting signal (%))
・
The value of the 1
st
frequency setting signal (%) depends on the value of
parameter “P004: Frequency Setting Signal”. But when parameter “P004:
Frequency Setting Signal” is specified as “1” or “7”, parameter “P111: PID
Target Value” can be used.
Related parameters: P004, P036 to P040, P106 to P111, P125 to P127, P157
Содержание VF200
Страница 1: ...VF200 WME VF200 A 2013 01 panasonic net id pidsx global ...
Страница 2: ......
Страница 7: ......
Страница 8: ...1 Safety Precautions ...
Страница 14: ...Safety Precautions 7 7 Warning Label on Inverter VF200 ...
Страница 15: ...Safety Precautions 8 ...
Страница 16: ...9 Points for Handling Special Precautions 10 ...
Страница 19: ...Points for Handling ...
Страница 20: ...13 1 Parts Identification 1 1 Part Names and Functions 14 1 2 Details on Part Number 16 ...
Страница 29: ...2 Installation 22 VF200 ...
Страница 49: ...42 ...
Страница 56: ...4 Operation Method Basic Operation ...
Страница 66: ...4 Operation Method Basic Operation 7 Stop operation Press button The motor starts to decelerate till to stop ...
Страница 75: ...4 Operation Method Basic Operation ...
Страница 76: ...69 5 Control Status Monitor 5 1 List of Control Status Monitor Items 70 5 2 Introduction of Monitor No 72 ...
Страница 88: ...81 6 Function Parameters 6 1 Setting and Changing Function Parameters 8 6 2 Function Parameter List 83 ...
Страница 101: ...6 Function Parameters 94 ...
Страница 102: ...95 7 Custom Mode 7 1 Allocating Parameter No 96 7 2 Setting and Changing Parameters 98 ...
Страница 107: ...7 Custom Mode 100 ...
Страница 119: ...8 Setting Mode and Copy Function of Built in Memory 112 ...
Страница 126: ...9 Troubleshooting 119 9 3 3 Breaker Trip 9 3 4 Motor Overheating 9 3 5 Communication Failed ...
Страница 127: ...9 Troubleshooting 120 ...
Страница 136: ...129 11 Specifications 11 1 Rated Specifications 130 11 2 Standard Specifications 132 11 3 Common Specifications 133 ...
Страница 145: ...11 Specifications 138 ...
Страница 146: ...139 Appendix Function Parameter List ...
Страница 208: ...Appendix Function Parameter List 201 ...