6. Function Parameters
90
No.
Function name
Changeable
during
operation
Setting range
Unit Initial value
Reference
page
P095 Current Sensing Level
0.1 to 100.0
A
*1
P.217
P096
Current Sensing Delay
Time
0.1 to 10.0
0.1
P.217
P097
Analog and PWM Output
Function Select
0·1
-
0
P.217
P098
Analog and PWM Output
Voltage Compensation
25 to 100
sec
100
P.219
P099 Lower Frequency Limit
0.5 to 400.0
Hz 0.5
P.219
P100 Upper Frequency Limit
0.5 to 400.0
Hz 400.0
P.219
P101 0V Stop Function Select
0000,0.5 to 400.0 Hz 0.5
P.220
P102 Bias/Gain Function Select
0·1
-
0
P.221
P103 Bias Frequency Setting
-99.0 to 250.0
%
0
P.221
P104 Gain Frequency Setting
0.0 to 500.0
%
100
P.221
P105 Analog Input Filter
5 to 200
Times 10
P.222
P106 PID Control Mode
0 to 3, A0 to A3
-
0
P.223
P107 Proportional Gain [Kp]
0.1 to 1000
-
1
P.225
P108 Integral Time [Ti]
0000·0.1 to 3600 sec
0
P.225
P109 Derivative Time [Td]
0000·0.1 to 3600 sec
0
P.225
P110 Control Cycle [Ts]
0.01 to 60.00
sec
0.01
P.225
P111 PID Target Value
0.0 to 100.0
%
100.0
P.225
P112 The 1
st
Skip Frequency
0000,0.5 to
400.0
Hz 0000
P.229
P113 The 2
nd
Skip Frequency
0000,0.5 to
400.0
Hz 0000
P.229
P114 The 3
rd
Skip Frequency
0000,0.5 to
400.0
Hz 0000
P.229
P115
Skip Frequency Band
Width
0 to 10
Hz 0
P.229
P116 The 2
nd
Base Frequency
45.0 to 400.0
Hz 50.0
P.230
P117 The 2
nd
Torque Boost
*6
Auto·0 to 40
%
5
(1-phase)
4
(3-phase)
P.231
P118
The 2
nd
Electronic Thermal
Select
0 to 3
-
2
P.233
Содержание VF200
Страница 1: ...VF200 WME VF200 A 2013 01 panasonic net id pidsx global ...
Страница 2: ......
Страница 7: ......
Страница 8: ...1 Safety Precautions ...
Страница 14: ...Safety Precautions 7 7 Warning Label on Inverter VF200 ...
Страница 15: ...Safety Precautions 8 ...
Страница 16: ...9 Points for Handling Special Precautions 10 ...
Страница 19: ...Points for Handling ...
Страница 20: ...13 1 Parts Identification 1 1 Part Names and Functions 14 1 2 Details on Part Number 16 ...
Страница 29: ...2 Installation 22 VF200 ...
Страница 49: ...42 ...
Страница 56: ...4 Operation Method Basic Operation ...
Страница 66: ...4 Operation Method Basic Operation 7 Stop operation Press button The motor starts to decelerate till to stop ...
Страница 75: ...4 Operation Method Basic Operation ...
Страница 76: ...69 5 Control Status Monitor 5 1 List of Control Status Monitor Items 70 5 2 Introduction of Monitor No 72 ...
Страница 88: ...81 6 Function Parameters 6 1 Setting and Changing Function Parameters 8 6 2 Function Parameter List 83 ...
Страница 101: ...6 Function Parameters 94 ...
Страница 102: ...95 7 Custom Mode 7 1 Allocating Parameter No 96 7 2 Setting and Changing Parameters 98 ...
Страница 107: ...7 Custom Mode 100 ...
Страница 119: ...8 Setting Mode and Copy Function of Built in Memory 112 ...
Страница 126: ...9 Troubleshooting 119 9 3 3 Breaker Trip 9 3 4 Motor Overheating 9 3 5 Communication Failed ...
Страница 127: ...9 Troubleshooting 120 ...
Страница 136: ...129 11 Specifications 11 1 Rated Specifications 130 11 2 Standard Specifications 132 11 3 Common Specifications 133 ...
Страница 145: ...11 Specifications 138 ...
Страница 146: ...139 Appendix Function Parameter List ...
Страница 208: ...Appendix Function Parameter List 201 ...