3. Wiring
3.4.2 Common Precautions on Terminals for Control Circuit
■
Precautions on Wiring
·
For wiring of terminals of control circuit, strip specified length of insulation
coating before connecting.
·
Loosen the terminal screws and insert the wires from bottom of the terminal
block, and tighten the screws to specified tightening torque.
·
Twist the strands of stripped wires, avoiding length variance.
Also, do not solder them.
·
Any loose connection could cause wire to come off and lead to malfunction.
Also, over-tightening could cause short-circuit due to screws and the unit
broken, thus lead to malfunction.
·
Use shielded cables for all control signal lines and separate them from power
lines or high-voltage circuits (20 cm or more).
·
Wiring length of control signal lines should be within 30 m.
·
Since input signals of control circuit are feeble, use dedicated terminals for
feeble signals to avoid poor contact during contact input.
■
Wire Size and Tightening Torque for Control Circuit Terminal
Terminal
symbol
Screw size
Tightening torque
N
·
m
Wire size
Stripping
length of wire
A, B, C
M3
0.5 to 0.6
0.25 to 0.75 mm
2
(AWG24 to AWG18)
6 mm
①~
M2
0.22 to 0.25
0.25
~
0.75 mm
2
(AWG24 to AWG18)
5 mm
·
Screwdriver: Small-size
㊀
screwdriver
(Thickness of the edge: 0.4 mm/ Width of the edge: 2.5 mm)
·
Removed length of
insulation
Содержание VF200
Страница 1: ...VF200 WME VF200 A 2013 01 panasonic net id pidsx global ...
Страница 2: ......
Страница 7: ......
Страница 8: ...1 Safety Precautions ...
Страница 14: ...Safety Precautions 7 7 Warning Label on Inverter VF200 ...
Страница 15: ...Safety Precautions 8 ...
Страница 16: ...9 Points for Handling Special Precautions 10 ...
Страница 19: ...Points for Handling ...
Страница 20: ...13 1 Parts Identification 1 1 Part Names and Functions 14 1 2 Details on Part Number 16 ...
Страница 29: ...2 Installation 22 VF200 ...
Страница 49: ...42 ...
Страница 56: ...4 Operation Method Basic Operation ...
Страница 66: ...4 Operation Method Basic Operation 7 Stop operation Press button The motor starts to decelerate till to stop ...
Страница 75: ...4 Operation Method Basic Operation ...
Страница 76: ...69 5 Control Status Monitor 5 1 List of Control Status Monitor Items 70 5 2 Introduction of Monitor No 72 ...
Страница 88: ...81 6 Function Parameters 6 1 Setting and Changing Function Parameters 8 6 2 Function Parameter List 83 ...
Страница 101: ...6 Function Parameters 94 ...
Страница 102: ...95 7 Custom Mode 7 1 Allocating Parameter No 96 7 2 Setting and Changing Parameters 98 ...
Страница 107: ...7 Custom Mode 100 ...
Страница 119: ...8 Setting Mode and Copy Function of Built in Memory 112 ...
Страница 126: ...9 Troubleshooting 119 9 3 3 Breaker Trip 9 3 4 Motor Overheating 9 3 5 Communication Failed ...
Страница 127: ...9 Troubleshooting 120 ...
Страница 136: ...129 11 Specifications 11 1 Rated Specifications 130 11 2 Standard Specifications 132 11 3 Common Specifications 133 ...
Страница 145: ...11 Specifications 138 ...
Страница 146: ...139 Appendix Function Parameter List ...
Страница 208: ...Appendix Function Parameter List 201 ...