8-40
8-5 Interface Monitor Setting Parameters
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
8
Parameters Details
Set the number of motor rotations from when the OFF of Run command (RUN) is detected to when
the Brake interlock output (BKIR) becomes off, in case when the servo off occurs during the motor
rotation.
Refer to "6-5 Brake Interlock (P.6-13)".
Pn439
Brake Release Speed Setting
Setting
range
30 to 3000
Unit
r/min
Default
setting
30
Data
attribute
B
All
Brake Release
(ON)
Brake Release
(ON)
Brake Engage (OFF)
Brake Engage (OFF)
Motor rotation speed
Pn439 set value
Pn438
set value
Pn438
set value
Motor rotation speed
Pn439 set value
When the Pn438 set
value is reached earlier
When the timing to reach the
Pn439 set value comes earlier
Pn439
set value