![Omron OMNUC G5 R88D-KN series Скачать руководство пользователя страница 157](http://html1.mh-extra.com/html/omron/omnuc-g5-r88d-kn-series/omnuc-g5-r88d-kn-series_user-manual_742785157.webp)
3-76
3-4 Cable and Connector Specifications
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
3
Specifications
Terminal Block Wiring Example
The example is common for XW2B-20G4, -20G5, and XW2D-20G6.
*1. Assign the brake interlock output (BKIR) to CN1-1 pin.
*2. This is the absolute encoder backup battery of 2.8 to 4.5 V. Secure the battery in place by cable clips
with double-sided adhesive tape. Connect the battery to either the connector terminal block or the
absolute encoder backup battery cable (with a battery). The absolute encoder backup battery is not
required when the Servomotor is equipped with an incremental encoder.
*3. The XB contact is used to turn ON/OFF the electromagnetic brake.
+
24 V
0 V
+
24 V
+
24 V
POT
EXT1
EXT3
BAT
BKIR
ALM
0 V
0 V
DEC
EXT2
BATGND
NOT
BKIRCOM
FG
24 VDC
24 VDC
*3
*2
*1
ALMCOM
XB
X1
STOP