A-3
A-1 Parameter List
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
A
Appe
ndix
Gain Parameters
Pn No.
Parameter name
Function and description
Default
setting
Unit
Setting
range
Data
attribute
100
Position Loop
Gain 1
Set the position loop gain 1.
320/
480
*1
0.1/s
0 to 30000
B
101
Speed Loop Gain
1
Set the speed loop gain 1.
180/
270
*2
0.1 Hz 1 to 32767
B
102
Speed Loop Integral
Time Constant 1
Set the speed loop integration time constant
1.
210/
310
*3
0.1 ms
1 to
10000
B
103
Speed Feedback
Filter Time Constant 1
The speed feedback filter 1 can be set to
one of 6 values.
0
0 to 5
B
104
Torque Command
Filter Time Constant 1
Set the time constant for the torque filter
1.
84/
126
*4
0.01
ms
0 to 2500
B
105
Position Loop
Gain 2
Set the position loop gain 2.
380/
570
*5
0.1/s
0 to 30000
B
106
Speed Loop Gain
2
Set the speed loop gain 2.
180/
270
*6
0.1 Hz 1 to 32767
B
107
Speed Loop Integration
Time Constant 2
Set the speed loop integration time constant
2.
10000 0.1 ms
1 to
10000
B
108
Speed Feedback
Filter Time Constant 2
The speed feedback filter 2 can be set to
one of 6 values.
0
0 to 5
B
109
Torque Command
Filter Time Constant 2
Set the time constant for the torque filter
2.
84/
126
*7
0.01
ms
0 to 2500
B
110
Speed Feed-
forward Amount
Set the speed feed-forward amount.
300
0.1% 0 to 1000
B
111
Speed Feed-forward
Command Filter
Set the speed feed-forward filter time
constant.
50
0.01
ms
0 to 6400
B
112
Torque Feed-
forward Amount
Set the torque feed-forward amount.
0
0.1% 0 to 1000
B
113
Torque Feed-forward
Command Filter
Set the torque feed-forward filter.
0
0.01
ms
0 to 6400
B
114
GAIN SWITCHING
INPUT
OPERATING
mode Selection
Execute optimum tuning using the gain
switching function.
0: Gain 1 (PI/P switching enabled)
1: Gain 1 and gain 2 switching available
1
0 to 1
B
*1. It is set to 320 when the Servo Drive capacity is 200 V and 1 kW or over, or 400 V.
It is set to 480 for other types of Serve Drives.
*2. It is set to 180 when the Servo Drive capacity is 200 V and 1 kW or over, or 400 V.
It is set to 270 for other types of Serve Drives
*3. It is set to 310 when the Servo Drive capacity is 200 V and 1 kW or over, or 400 V.
It is set to 210 for other types of Serve Drive
*4. It is set to 126 when the Servo Drive capacity is 200 V and 1 kW or over, or 400 V.
It is set to 84 for other types of Serve Drives
*5. It is set to 380 when the Servo Drive capacity is 200 V and 1 kW or over, or 400 V.
It is set to 570 for other types of Serve Drives.
*6. It is set to 180 when the Servo Drive capacity is 200 V and 1 kW or over, or 400 V.
It is set to 270 for other types of Serve Drives.
*7. It is set to 126 when the Servo Drive capacity is 200 V and 1 kW or over, or 400 V.
It is set to 84 for other types of Serve Drives.
Содержание OMNUC G5 R88D-KN series
Страница 22: ......
Страница 164: ......
Страница 228: ......
Страница 274: ......
Страница 342: ......
Страница 392: ......
Страница 432: ......
Страница 450: ......
Страница 451: ...I OMNUC G5 Series AC Servo Drives Users Manual Built in MECHATROLINK II communications type Index ...
Страница 456: ......
Страница 457: ......