INTRODUCTION.

 The wireless four-channel multifunctional receiver 

ACS-146R

, operating in conjunction with two hand-held 

push-button transmitters, provides the remote control of any electronic equipment: ELECTRICAL GATES, SLIDING DOORS, 
ELECTROMAGNETIC LOCKS, AUTOMATIC BARRIERS, ELECTRICAL CURTAINS, LIGHTING FIXTURES, etc. 
The remote control set may be used as a PANIC BUTTON in security systems for creating any type of alarm. 

--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

 

KEELOQ

®

 CODE HOPPING TECHNOLOGY. 

The wireless

 

remote control set 

ACS-146R

 uses KEELOQ

®

 highly secure algorithm. 

The combinations of different codes transmitted by remote controls prevent radio scanning and unauthorized access. 

--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

 

ACS-146R FEATURES.

 

 

 

FOUR INDEPENDENT CHANNELS. 

 

FIVE OPERATING MODES OF EACH RECEIVER CHANNEL: 

 

1. 

PULSE MODE - 1SECOND.  

2. 

SWITCH ON PERIOD MODE (1 – 300 sec).  

3.

 SWITCHING MODE (ON/OFF).

 

4. 

HOLD MODE (CONTINUOUS).  

5.

 PANIC BUTTON MODE (SECURITY). 

 

  Power input: AC/DC 24V 

  Receiving range in open space - up to 500 meters 

 KEELOQ

®

 code hopping technology 

  Maximum quantity of remote controls learning the receiver – 330 pieces 

  Programming the ON/OFF period for the desired time from 1 to 300 sec 

  Unauthorized access protection (in “Panic Button” mode) 

 

Last event memory: 30min (in “Panic Button” mode)

 

 

The alarm comes on when the electric power supply is disconnected (in “Panic Button” mode)

 

--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

 

SETTING THE RECEIVER OPERATING MODES. 

 

1. «PULSE» MODE»

 - 

1 SECOND

 (default setting).

 

FIRST CHANNEL 

SECOND CHANNEL 

THIRD CHANNEL 

FOURTH CHANNEL 

“SEC-1” is installed. 

“TLG-1” is installed.

 

“SEC-2” is installed. 

“TLG-2” is installed.

 

“SEC-3” is installed 

“TLG-3” is installed. 

“SEC-4” is installed. 

“TLG-4” is installed.

 

 

Pressing the remote control button (A) activates the relay of the first receiver channel for 1 second. 
Pressing the remote control button (B) activates the relay of the second receiver channel for 1 second. 
Pressing the remote control button (C) activates the relay of the third receiver channel for 1 second. 
Pressing the remote control button (D) activates the relay of the forth receiver channel for 1 second. 

 

2.

 

«SWITCH ON PERIOD»

 

MODE (1-300 SECOND). 

PROGRAMMING "SWITCH ON PERIOD" MODE. 

FIRST CHANNEL 

SECOND CHANNEL 

THIRD CHANNEL 

FOURTH CHANNEL 

“SEC-1” is installed. 

“TLG-1” is installed.

 

“SEC-2” is installed. 

“TLG-2” is installed.

 

“SEC-3” is installed 

“TLG-3” is installed. 

“SEC-4” is installed. 

“TLG-4” is installed.

 

 

A. Press and hold the "Tact switch” button (SW2) . The LED will turn OFF and 5 seconds after will turn ON. Release (SW2) button. 
B. Press and release remote control button (A) – the relay of the first receiver channel is activated. The LED starts to 
blink indicating that the receiver has begun to memorize the required time period from 1 to 300 sec. 
C. Press and release the same remote control button to finish programming the ON/OFF period for the user-definable time 
from 1-300 sec. The LED will turn ON - “SWITCH ON PERIOD” MODE is programmed. 

¾

 To change the ON/OFF period in “SWITCH ON PERIOD” MODE, perform steps A to C above. 

¾

 To program “SWITCH ON PERIOD” MODE for second, third

 

or

 

fourth receiver channel repeat steps A to C using 

remote control buttons

 

(B), (C) or (D). 

 

RESET TO FACTORY DEFAULT SETTING («PULSE MODE» - 1 SECOND). 

Jumpers ''SEC-1'' ''TGL-1'', ''SEC-2'' ''TGL-2'', ''SEC-3'' ''TGL-3'', ''SEC-4'' ''TGL-4'  – are installed. 
A. Press and hold the "Tact switch” button (SW2). The LED will turn OFF and 5 seconds after will turn ON. Release (SW2) button. 
B. Press and hold the "Tact switch” button (SW1)  during 5 seconds – LED starts to blink and then will be continuously lit. 
C. Release (SW1) button – the operating mode of the first receiver channel has been reset to its original factory default. 

¾

 To reset the operating mode of second, third or fourth receiver channel to default setting perform steps A to C above, but press and 

hold the "Tact switch” button (SW1) during 10 seconds for second receiver channel, 20 seconds for third receiver channel or 30 seconds 
for forth receiver channel  in Step B. 

 

3. «SWITCHING MODE» (ON/OFF). 

 

FIRST CHANNEL 

SECOND CHANNEL 

THIRD CHANNEL 

FOURTH CHANNEL 

“SEC-1” is installed. 

“TLG-1” is removed.

 

“SEC-2” is installed. 

“TLG-2” is removed.

 

“SEC-3” is installed 

“TLG-3” is removed. 

“SEC-4” is installed. 

“TLG-4” is removed.

 

 

Each pressing the remote control button corresponds to one of the relay positions (ON/OFF). 

 

4. «HOLD MODE (CONTINUOUS)». 

 

FIRST CHANNEL 

SECOND CHANNEL 

THIRD CHANNEL 

FOURTH CHANNEL 

“SEC-1” is removed. 
“TLG-1” is installed.

 

“SEC-2” is removed. 
“TLG-2” is installed.

 

“SEC-3” is removed. 

“TLG-3” is installed. 

“SEC-4” is removed. 
“TLG-4” is installed.

 

 

The receiver relay is activated during the continuous pressing the remote control button (maximum 25 second). 

 

 