99
Connecting External I/O for Slave Units
Section 3-6
The cables are held between the sealing section cover and sealing section
housing to ensure resistance to splashing.
For cables with smaller outer diameters, the sealing pieces can be used to
ensure splash resistance.
Applicable Cables
The range of outer diameters of cables that can be connected is 2.2 to
6.3 mm. When the diameter is within the range of 2.2 to less than 3.6 mm,
then the sealing section for small-diameter cables must be attached.
Installation Method
1,2,3...
1.
Expand the split in the sealing piece and insert the cable.
2.
Place the groove on the sealing pieces onto the inside of the housing to
secure it. (See following diagram.)
Handling
Unconnected
Terminals
For terminals that are not connected, insert an NC pin into the small cable
sealing piece as shown in the following diagram. Then secure the sealing
piece onto the housing as described above.
Tightening the Cover
Finally, close the cover and tighten the cover screws.
The tightening torque is 0.8 to 1.0 N·m.
Split
Содержание CRT1 - 10-2008
Страница 2: ...CRT1 Series CompoNet Slave Units and Repeater Unit Operation Manual Revised October 2008...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 23: ...xxiv Conformance to EC Directives 6...
Страница 51: ...28 Slave Unit Models Section 1 2...
Страница 123: ...100 Connecting External I O for Slave Units Section 3 6...
Страница 365: ...342 Temperature Input Units Section 7 5...
Страница 381: ...358 Expansion Unit Specifications Section 8 2...
Страница 418: ...395 Repeater Unit Section 10 2 Dimensions 42 3 50 3 1 27 5 95 mm...
Страница 419: ...396 Repeater Unit Section 10 2...
Страница 424: ...401 CX Integrator Section 11 1...
Страница 575: ...552 Current Consumption Summary Appendix D 552...
Страница 581: ...558 Index...
Страница 583: ...560 Revision History...