451
Analog I/O Slave Unit Functions
Section 11-4
Setting Using the CX-Integrator
1,2,3...
1.
Turn ON the power supply to the CompoNet Slave Unit.
2.
Double-click the icon of the Slave Unit to set in the Network Configuration
Window to open the Configuration Window. (Alternatively, right-click the
icon and select
Parameters - Edit
from the pop-up menu.)
3.
Select the tab page for the output where the cumulated counter is to be set,
and select the
Cumulated Count
Check Box under the
Function Choice
heading.
4.
To set the counter unit, click the
Cumulated Count
Tab and select
Hour
or
Minute
from the pull-down menu in the
Cumulated Time
Field.