23
Slave Unit Models
Section 1-2
1-2-2
Bit Slave Units
Slaves with Connectors
Slaves with Clamp Terminal Blocks
Note
Bit Slaves have Standard or Sheathed Flat Cable connected as standard fea-
ture. They cannot be at a baud rate of 4 Mbps, for which branch lines are not
supported.
1-2-3
Repeater Units
Type
Appearance
I/O capacity
Model
Features
Bit Slave Units with e-
CON Connectors
2 inputs (NPN)
CRT1B-ID02S
• Standard Flat Cable connected as
standard feature.
2 inputs (PNP)
CRT1B-ID02S-1
2 outputs (NPN)
CRT1B-OD02S
2 outputs (PNP)
CRT1B-OD02S-1
2 inputs (NPN)
CRT1B-ID02SP
• Sheathed Flat Cable connected
as standard feature.
• IP54 dust-tight and splash-proof
2 inputs (PNP)
CRT1B-ID02SP-1
2 outputs (NPN)
CRT1B-OD02SP
2 outputs (PNP)
CRT1B-OD02SP-1
4 inputs (NPN)
CRT1B-ID04SP
4 inputs (PNP)
CRT1B-ID04SP-1
Type
Appearance
I/O capacity
Model
Features
Bit Slave Units with
Screw-less Clamp
Terminal Blocks
2 inputs/2 outputs
(NPN)
CRT1B-MD04SLP
• Sheathed Flat Cable connected
as standard feature.
• IP54 dust-tight and splash-proof
2 inputs/2 outputs
(PNP)
CRT1B-MD04SLP-1
Appearance
Specification
Model
Features
Two communications connec-
tors (Upstream port and down-
stream port)
One downstream port power
supply connector
Up to 64 Units can be con-
nected for each Master Unit.
CRS1-RPT01
• For trunk line-branch line formations, sub-trunk
lines can be connected under a Repeater Unit
just like they can be under the Master Unit.
• For unrestricted branching formations, there are
no restrictions on the connections.
• Repeater Units enable branching the trunk line,
adding more nodes, increasing the connection
distance, and changing the type of cable
upstream and downstream of the Repeater Unit.
POR
T2
POR
T2
POR
T1
POR
T1
PRT
PRT
NO
DE
ADR
NO
DE
ADR
NET
WO
RK P
OW
ER S
UPP
LY
NET
WO
RK
POW
ER
SUP
PLY
OMRON
OM
RO
N
CR
S1-P
RT
01
CR
S1-
PR
T01
RP
T
RP
T
X10
X10[0-63]
[0-
63
]
X1
X1
DC24V
DC2
4V
INPU
T
INP
UT
S M
S
MS
Содержание CRT1 - 10-2008
Страница 2: ...CRT1 Series CompoNet Slave Units and Repeater Unit Operation Manual Revised October 2008...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 23: ...xxiv Conformance to EC Directives 6...
Страница 51: ...28 Slave Unit Models Section 1 2...
Страница 123: ...100 Connecting External I O for Slave Units Section 3 6...
Страница 365: ...342 Temperature Input Units Section 7 5...
Страница 381: ...358 Expansion Unit Specifications Section 8 2...
Страница 418: ...395 Repeater Unit Section 10 2 Dimensions 42 3 50 3 1 27 5 95 mm...
Страница 419: ...396 Repeater Unit Section 10 2...
Страница 424: ...401 CX Integrator Section 11 1...
Страница 575: ...552 Current Consumption Summary Appendix D 552...
Страница 581: ...558 Index...
Страница 583: ...560 Revision History...