47
OPERATING PROCEDURES
:
Setting Processing Conditions and Entering Layout Data
2
2.5.3
Entering layout data for bifocal lenses
The ICE-1000 automatically blocks bifocal lenses by detecting the segment base point (top line center
of segment).
According to prescription, enter lens layout data (FPD, near PD, and height of the optical center).
As the layout mode for the bifocal lenses, select passive (PAS) mode.
1
Set the lens type to Multi (bifocal lens).
2
Enter the FPD (or DBL).
3
Enter the prescribed near PD (PD for the segment) at the PD (or 1/2 PD) field.
4
Select a method to enter the optical center height.
Pressing the
button displays the pop-up menu. Press the PD
or BT
button to select
the entry method.
Safety beveling
Flat edging
ø
32 mm
ø
25 mm
Beveling
ø
34 mm
ø
26 mm
• When the lenses have an excessively short vertical diameter that the processing wheels
may come in contact with the lens cup, even when using a lens cup for half-eye lenses, the
yellow cup mark changes to red to warn the operator of a possibility of contact.
In such a case, change the layout mode to Passive and then block the lens. It is unnecessary to
change the lens layout data.
• If the lenses have a specific segment in shape (e.g. circular segment), the segment position
cannot be detected and the lenses cannot be blocked. Manually block such lenses (with
manual mode).
In such cases, mark the lenses using the lensmeter, and set the lens type to Manual.
Base point
(Top line center of segment)
Near PD