4308
VOLTAGE DROP
(CONVERTER)
[Bit Pattern]
• Direct current power supply voltage sup-
plied to amplifier for servopack has
become less than143V.
Reason is follows:
• Primary power supply voltage was too low.
• There was open phase.
• Defective converte
• Defective WRCA01circuit boar
• Check the connection for primary side
wiring R,S,T, wire.
• Check that power supply voltage is more
than 170V.
• If the error occurs again, replace the
WRCA01, WRCF01 circuit board, the
converter.
4309
DEFECTIVE
ENCODER INTER-
NAL DATA
Robot/Station
[Axis Data]
The internal parameter error for serial
encoder. It is thought the encoder was
abnormal.
• Turn the power off then back on. If a
phenomenon occurs again after repeat-
ing this operation several times, replace
the motor (encoder) for axis occurred the
error.
• If the error occurs again, consult with a
YASKAWA representative.
4310
ENCODER OVER-
HEAT
Robot/Station
[Axis Data]
The encoder has overheated to 100
degrees.
• Check that the ambient temperature is
not too high.
• Check the load again.
• Check the primary power supply voltage
(220V+10%).
• If the error occurs again, replace the
WRCA01 circuit board, the encoder.
4311
ENCODER BACK-UP
ERROR
Robot/Station
[Axis Data]
• Because backup power supply voltage for
encoder decreased (less than 2.6V), posi-
tion data of the encoder disappeared.
• Whenever a new motor was used, this
error occurred.
• Reset the alarm. Adjust the home posi-
tion again.
• Check the battery voltage for encoder.
(more than 2.8V)
• Replace the battery.
• If the error occurs again, replace the
encoder.
• Because it is charged the backup con-
denser, don't turn off power supply for a
few minutes.
4312
ENCODER BAT-
TERY ERROR
Robot/Station
[Axis Data]
Voltage of backup battery for encoder has
decreased.(less than 2.8V)
(In case leaving this voltage as it is, the
backup error occurs and position data dis
appears.)
• Check the battery voltage for encoder.
(more than 2.8V)
• Replace the battery.
4313
SERIAL ENCODER
OVER HEAT
Robot/Station
[Axis Data]
The encoder has overheated to 100
degrees.
• Check that the ambient temperature is
not too high.
• Check the load again.
• Check the primary power supply voltage
(220V+10%).
• If the error occurs again, replace the
WRCA01 circuit board, the encoder.
4314
SERIAL ENCODER
BATTERY ERROR
Robot/Station
[Axis Data]
Voltage of backup battery for encoder has
decreased.(less than 2.8V)(In case leaving
this voltage as it is, the backup error occurs
and position data disappears.
• Check the battery voltage for encoder.
(more than 2.8V)
• Replace the battery.
Alarm Message List
Alarm
Number
Message
Cause
Remedy
Содержание SK300X
Страница 2: ......
Страница 4: ...SK300X Manipulator Manual XRC 2001 ii MOTOMAN NOTES...
Страница 7: ...INTRODUCTION MOTOMAN 1 3 SK300X Manipulator Manual XRC 2001 NOTES...
Страница 21: ...viii...
Страница 25: ...xii...
Страница 41: ...1 7 Notes on MOTOMAN Disposal 1 16...
Страница 59: ...4 3 Connection Methods 4 12...
Страница 67: ...6 1 Movement of the Axes 6 4...
Страница 73: ...8 2...
Страница 74: ......
Страница 93: ...3 3 Location 3 6...
Страница 99: ...4 2 Cable Connection 4 6...
Страница 102: ...5 4 Dimensions and Working Range 5 3 5 4 Dimensions and Working Range Fig 10 a Dimesions and Working Range YR SK300 J0...
Страница 103: ...5 4 Dimensions and Working Range 5 4 Fig 10 b Dimesions and Working Range YR SK300 J1...
Страница 104: ...5 4 Dimensions and Working Range 5 5 Fig 10 c Dimesions and Working Range YR SK300 J2...
Страница 109: ...6 2 Wrist Flange 6 4...
Страница 133: ...9 2 Notes on Maintenance Procedures 9 18...
Страница 136: ...11 1 S Axis Driving Unit 11 1 11 Parts List 11 1 S Axis Driving Unit...
Страница 138: ...11 2 L U Axis Driving Unit 1 11 3 11 2 L U Axis Driving Unit 1...
Страница 140: ...11 3 L U Axis Driving Unit 2 11 5 11 3 L U Axis Driving Unit 2...
Страница 234: ...2 8 General I O Signal Assignment 2 72...
Страница 270: ...4 4 Recommended Spare Parts 4 30...
Страница 285: ...xiv...
Страница 286: ...Setup Diagnosis...
Страница 287: ......
Страница 289: ...1 2...
Страница 297: ...2 1 Protection Through Security Mode Settings 2 8...
Страница 395: ...3 17 File Initialize 3 98...
Страница 417: ...4 2 Addition of Base and Station Axis 4 22...
Страница 435: ...5 6 Position Data When Power is Turned ON OFF 5 18...
Страница 436: ...Hardware...
Страница 437: ......
Страница 447: ...6 4 Equipment Configuration 6 10...
Страница 456: ...8 8 Open Phase Check 8 8...
Страница 476: ...9 4 Recommended Spare Parts 9 20...
Страница 477: ...Alarm Error...
Страница 478: ......
Страница 523: ......
Страница 524: ......
Страница 525: ......
Страница 526: ......
Страница 527: ......
Страница 528: ......
Страница 529: ......
Страница 530: ......
Страница 531: ......
Страница 532: ......
Страница 533: ......
Страница 534: ......
Страница 535: ......
Страница 536: ......
Страница 537: ......
Страница 538: ......
Страница 539: ......
Страница 540: ......
Страница 541: ......
Страница 542: ......
Страница 543: ......
Страница 544: ......
Страница 545: ......
Страница 546: ......
Страница 547: ......
Страница 548: ......
Страница 549: ......
Страница 550: ......
Страница 551: ......
Страница 552: ......
Страница 553: ......