Part 5: Review on Replacement of MR-J3-DU_ with MR-J4-DU_
5 - 12
(1) 200 V class
(a) MR-J3-DU_A/MR-J4-DU_A
MR-J3-DU_A MR-J4-DU_A
Regenerative
RA1
RA2
RA3
option(Note 1)
Converter
-ready
OFF/ON
unit trouble
Servo motor
Operation
thermal relay
Drive
unit trouble
(EMG/EM1)
Emergency stop
(Note 3)
MC
SK
NFB
MC
(Note 5)
(Note 4)
supply
Power
BW
BV
BU
Termination
connector
MR-J3-TM
Power factor improving
DC reactor (Option)
L+
L-
(Option)
cable
MR-J3CDL05M
Drive unit
Converter unit
L
1
L
2
L
3
L
11
L
21
1
2
MC1
3-phase
200 to 230 V AC
50/60 Hz
MC2
CN40
CN40A
CN2
External
dynamic brake
(Option)
Servo
motor
thermal
relay
OHS1
M
OHS2
V
Encoder
U
W
CN40B
V
U
W
L+
TE2-2
L-
Servo motor
TE2-1
C
L
11
L
21
C
P
C
P
R1
S1
G4
G3
C
P
Cooling fan
R1
S1
R1
S1
CNP1
CN1
EMG
46
42
SON
DICOM
21
ALM
48
DOC O M
20
DICOM
SD
15
Plate
(Note 3)
CN1
1
DICOM
5
DOC OM
6
DICOM
2
7
ALM
9
EM1
DOC OM
(Note 3)
24 V DC
P
1
P
2
(Note 2)
Cooling fan
24 V DC
Encoder cable
RA1
NFB
RA2
24 V DC
RA3
Regenerative
G4
G3
option(Note 1)
Cooling fan
Regenerative
G4
G3
option(Note 1)
Cooling fan
(Note 6)
RA3
RA1
RA2
Optional
thermal
Operation ready
OFF/ON
Drive unit
malfunction
Emergency stop
switch
MC
SK
MC
(Note 4)
MCCB
RA2
(Note 1)
Regenerative
option
L+
L-
MR-J3CDL05M
cable
Drive unit
L1
L2
L3
L11
L21
3-phase
200 V AC to
240 V AC
1
MC1
2
MC2
CN40
CN40A
(Note 11)
CN2
External
dynamic brake
(
optional
)
BV
M
Encoder
V
U
W
V
U
W
Servo motor
(Note 3)
Power
supply
TE2-2
L+
L-
TE2-1
C
P1
P2
Power factor improving
DC reactor (
optional
)
(Note 2)
L11
L21
G4
G3
P
C
G4
G3
P
C
S1
R1
G4
G3
P
C
Cooling fan
(Note 1)
Regenerative
option
Cooling fan
(Note 1)
Regenerative
option
Cooling fan
S1
R1
S1
R1
CNP1
CN1
1
DICOM
5
DOCOM
6
DICOM
2
ALM
7
EM1
9
DOCOM
(Note 7) Encoder cable
24 V DC
MCCB
BW
BU
Cooling fan
(Note 6, 13)
RA3
24 V DC
(Note 10)
Short-circuit connector
(packed with the drive unit)
CN8
(Note 11)
(Note 8)
(Note 12)
(Note 9)
(Note 9)
Resistance regeneration
converter unit
Converter unit
malfunction
CN1
SON
15
21
46
ALM
48
42
DOCOM
EM2
DICOM
24 V DC
Main circuit power supply
(Note 5)
RA1
24 V DC
Note 1. For the MR-RB137. For the MR-RB137, three units are used as one set
(permissible wattage: 3900W).
Note 1. This is for MR-RB137. For the MR-RB137, three units are used as one
set (permissible regenerative power: 3900 W).
2. When using the Power factor improving DC reactor, disconnect the short
bar across P1 and P2.
2. P1 and P2 are connected by default. When using the power factor
improving DC reactor, connect P1 and P2 after removing the short bar
across them. Refer to "Part 8: section 7.3" for details.
3. Make up a sequence that will concurrently turn off the Emergency stop
(EMG) of the drive unit and the Forced stop (EM1) of the converter unit,
and shut off the main circuit power supply by the external sequence.
3. For specifications of the cooling fan power supply, refer to "Servo Motor
Instruction Manual (Vol. 3)".
4. For specifications of cooling fan power supply, refer to "MR-J3-_A_ Servo
amplifier instruction manual"
4.
Use a magnetic contactor with an operation delay time (interval between
current being applied to the coil until closure of contacts) of 80 ms or less.
5. Be sure to use a magnetic contactor with an operation delay time of 80ms
or less. The operation delay time is the time interval between current
being applied to the coil until closure of contacts.
The bus voltage decreases depending on the main circuit voltage and
operation pattern, which may cause the forced stop deceleration to shift
to the dynamic brake deceleration. When dynamic brake deceleration is
6. Use an external dynamic brake for the drive unit. Failure to do so will
cause an accident because the servo motor does not stop immediately but
coasts at an emergency stop and such conditions. Ensure the safety in
the entire system.
not required, slow the time to turn off the magnetic contactor.
5. To prevent an unexpected restart of the drive unit, configure a circuit to
turn off EM2 in the drive unit when the main circuit power is turned off.
6. Use an external dynamic brake for the drive unit. Failure to do so will
cause an accident because the servo motor does not stop immediately
but coasts at an alarm occurrence for which the servo motor does not
decelerate to stop. Ensure the safety in the entire equipment. For alarms
for which the servo motor does not decelerate to stop and for wiring of the
external dynamic brake, refer to "MR-CV_/MR-CR55K_/MR-J4-DU_(-RJ)
instruction manual".
7. For the encoder cable, use of the option cable is recommended. For
selecting cables, refer to "Servo Motor Instruction Manual (Vol. 3)".
8. This diagram shows sink I/O interface. For source I/O interface, refer to
"MR-CV_/MR-CR55K_/MR-J4-DU_(-RJ) instruction manual".
9. Install an overcurrent protection device (molded-case circuit breaker or
fuse) to protect the branch circuit. (Refer to section 7.3.)
10. When not using the STO function, attach the short-circuit connector
supplied with the drive unit.
11. Do not connect a servo motor of the wrong axis to U, V, W, or CN2 of the
drive unit. Otherwise, a malfunction may occur.
12. For connecting servo motor power wires, refer to "Servo Motor Instruction
Manual (Vol. 3)".
13. The external dynamic brake cannot be used for compliance with SEMI-
F47 standard. Do not assign DB. Failure to do so will cause the drive unit
to become servo-off when an instantaneous power failure occurs.
Содержание Melservo MR-J3-100B
Страница 17: ...8 MEMO ...
Страница 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Страница 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Страница 146: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 1 Part 4 Review on Replacement of MR J3W _B with MR J4W2 _B ...
Страница 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Страница 196: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 1 Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ ...
Страница 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Страница 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Страница 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Страница 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Страница 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Страница 589: ...L NA 03127ENG C ...