Part 5: Review on Replacement of MR-J3-DU_ with MR-J4-DU_
5 - 57
7.4 FR-BU2-(H) brake unit
POINT
EM2 of the drive unit is the signal having the same contents as EM1 of the drive
unit in torque control mode. (J4 series)
Use a 200 V class brake unit and a resistor unit with a 200 V class converter
unit, and a 400 V class brake unit and a resistor unit with a 400 V class
converter unit. Combination of different voltage class units cannot be used.
When a brake unit and a resistor unit are installed horizontally or diagonally, the
heat dissipation effect diminishes. Install them on a flat surface vertically.
The temperature of the resistor unit case will be higher than the ambient
temperature by 100
˚
C or over. Keep cables and flammable materials away from
the case.
Ambient temperature condition of the brake unit is between -10 °C and 50 °C.
Note that the condition is different from the ambient temperature condition of the
converter unit (between 0 °C and 55 °C).
Configure the circuit to shut down the power-supply with the alarm output of the
brake unit and the resistor unit under abnormal condition.
Use the brake unit with a combination indicated in section 7.4.1.
Brake unit and regenerative options (Regenerative resistor) cannot be used
simultaneously.
When using the brake unit, set the parameters as follows.
Parameter
Setting
value
[Pr. PA01] of the resistance regeneration converter unit
_ _ 0 0
(Initial value)
MR-J3-DU_ drive unit of the [Pr. PA02]
_ _ 0 0
(Initial value)
MR-J4-DU_ drive unit of the [Pr. PA02]
_ _ 0 1
Connect the brake unit to the bus of the converter unit (L+ and L- of TE2-1) for use. As compared to the MR-
RB regenerative option, the brake unit can return larger power. Use the brake unit when the regenerative
option cannot provide sufficient regenerative capability.
When using the brake unit, always refer to "FR-BU2 Brake Unit Instruction Manual".
7.4.1 Selection
Use a combination of converter unit, brake unit and resistor unit listed below.
Brake unit
Resistor unit
Number of
connected
units
Permissible
continuous
power
[kW]
Resultant
resistance
[
Ω
]
Converter unit
200 V class FR-BU2-55K
FR-BR-55K
2 (parallel)
7.82 1
MR-J3-CR55K
MR-CR55K
MT-BR5-55K
2 (parallel)
11.0 1
400 V class
FR-BU2-H55K FR-BR-H55K
2 (parallel)
7.82 4
MR-J3-CR55K4
MR-CR55K4
FR-BU2-H75K MT-BR5-H75K 2 (parallel)
15.0 3.25
Содержание Melservo MR-J3-100B
Страница 17: ...8 MEMO ...
Страница 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Страница 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Страница 146: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 1 Part 4 Review on Replacement of MR J3W _B with MR J4W2 _B ...
Страница 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Страница 196: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 1 Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ ...
Страница 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Страница 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Страница 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Страница 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Страница 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Страница 589: ...L NA 03127ENG C ...