Part 6: Common Reference Material
6 - 32
(3) MR-J4W2-0303B6/MR-J3W-0303BN6 servo amplifier
The following graphs show overload protection characteristics.
0.1
1
10
100
1000
0
50
100
150
200
250
300
350
400
Servo-lock
Operation
O
peration time [s]
Load ratio [%]
HG-AK0136/HG-AK0236/HG-AK0336
(4) MR-J4-DU_(-RJ)/MR-J3- DU_ drive unit
The following graphs show overload protection characteristics.
10000
1000
100
10
1
300
50
100
150
200
250
0
Operat
ion t
ime [
s]
Servo-lock
Load ratio [%]
Operating
(Note)
Note Load ratio 100% indicates the rated output of the drive unit.
Содержание Melservo MR-J3-100B
Страница 17: ...8 MEMO ...
Страница 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Страница 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Страница 146: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 1 Part 4 Review on Replacement of MR J3W _B with MR J4W2 _B ...
Страница 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Страница 196: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 1 Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ ...
Страница 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Страница 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Страница 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Страница 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Страница 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Страница 589: ...L NA 03127ENG C ...