Part 3: Review on Replacement of MR-J3-_B_ with MR-J4-_B_
3 - 45
MR-J3-_B_
MR-J4-_B_
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PD17 Driver communication setting - Master - Transmit data
selection 2
This parameter setting is used with servo amplifier with
software version C1 or later. Check the software version
using Setup software (SETUP221E).
This parameter is used to select transmit data from
master axis to slave axis.
When setting this amplifier as master axis ([Pr. PD15] =
"0001"), select "003A (speed limit command)" with this
parameter.
0 0 x x:
Transmission data selection
00: Disabled
3A: speed limit command
0000h
PD17 Driver communication setting - Master - Transmit data
selection 2
This parameter is used to select transmit data from
master axis to slave axis.
When setting this amplifier as master axis ([Pr. PD15] is
"_ _ 0 1".), select "_ _ 3 A (speed limit command)" with
this parameter.
This parameter setting is used with servo amplifier with
software version A8 or later.
_ _ x x:
Transmission data selection
00: Disabled
3A: speed limit command
00h
_ x _ _ :
For manufacturer setting
0h
x _ _ _ :
For manufacturer setting
0h
PD20 Driver communication setting - Slave - Master axis No.
selection 1
This parameter setting is used with servo amplifier with
software version C1 or later. Check the software version
using Setup software (SETUP221E).
Select a master axis when this amplifier is slave axis.
When setting this amplifier as slave axis ([Pr. PD15] =
"0010"), set the axis No. of the servo amplifier of master.
Refer to MR-J4-_B_ Servo Amplifier Instruction Manual
for details of axis Nos.
0
PD20 Driver communication setting - Slave - Master axis No.
selection 1
Select a master axis when this amplifier is slave axis.
When setting this amplifier as slave axis ([Pr. PD15] is "_
_ 1 0".), set the axis No. of the servo amplifier of master.
Setting "0" disables this parameter.
This parameter setting is used with servo amplifier with
software version A8 or later.
0
PD30 Master-slave operation - Torque command coefficient on
slave
This parameter setting is used with servo amplifier with
software version C1 or later. Check the software version
using Setup software (SETUP221E).
This parameter is used to set an internal torque
command coefficient to torque command value received
from master axis.
This parameter is enabled when this amplifier is set as
slave axis ([Pr. PD15] = "0010"). Convert a decimal value
to a hexadecimal value for input. The maximum value is
500. Setting over 500 will be 500.
Setting 100 [%] (0064h in hexadecimal) means
multiplication of one. The torque ratio will be 100
(master) to 100 (slave). Setting 90 [%] (005Ah in
hexadecimal) means multiplication of 0.9. The torque
ratio will be 100 (master) to 90 (slave).
0000h PD30 Master-slave
operation
- Torque command coefficient on
slave
This parameter is used to set an internal torque
command coefficient to torque command value received
from master axis.
This parameter is enabled when this amplifier is set as
slave axis ([Pr. PD15] is "_ _ 1 0".). The maximum value
is 500. Setting over 500 will be 500.
Setting 100 [%] means multiplication of one. The torque
ratio will be 100 (master) to 100 (slave).
Setting 90 [%] means multiplication of 0.9. The torque
ratio will be 100 (master) to 90 (slave).
This parameter setting is used with servo amplifier with
software version A8 or later.
0
Содержание Melservo MR-J3-100B
Страница 17: ...8 MEMO ...
Страница 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Страница 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Страница 146: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 1 Part 4 Review on Replacement of MR J3W _B with MR J4W2 _B ...
Страница 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Страница 196: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 1 Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ ...
Страница 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Страница 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Страница 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Страница 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Страница 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Страница 589: ...L NA 03127ENG C ...