Part 8: Review on Replacement of Optional Peripheral Equipment
8 - 30
4.3.3 MR-J3W series, no-fuse breakers, fuses, magnetic contactors
Always use one molded-case circuit breaker and one magnetic contactor with one servo amplifier. When
using a fuse instead of the molded-case circuit breaker, use the one having the specifications given in this
section.
When using two different types of motors in combination from a rotary servo motor, a select a molded-case
circuit breaker, a fuse or a magnetic contactor temporarily assuming that the same type of the motors are
used for both axes. After selecting for the two types, use the larger molded-case circuit breaker, fuse or
magnetic contactor.
Total output of rotary servo motor
Molded-case circuit breaker
Fuse
Magnetic
contactor
(Note 2)
Current
Voltage
AC [V]
Class
(Note 1)
Current
[A]
Voltage
AC [V]
Not using power
factor improving
AC reactor
Using power
factor improving
AC reactor
300 W or less
30 A frame 5 A
30 A frame 5 A
240 K5
15
300
S-N10
From over 300W to 600W
30 A frame 10 A
30 A frame 10 A
20
From over 600W to 1kW
30 A frame 15 A
30 A frame 10 A
20
From over 1kW to 2.0kW
30 A frame 20 A
30 A frame 15 A
30
S-N18
Note 1. In order for the servo amplifier to comply with the UL/CSA standard, refer to the applicable "Servo Amplifier Instruction
Manual".
2. Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts) of 80 ms or less.
Servo amplifier
Power supply specification
Circuit protector (Note)
MR-J3W-0303BN6
Control circuit power supply (24 V DC)
CP30-BA 1P 1-M 1A
Main circuit power supply (48 V DC)
CP30-BA 1P 1-M 5A
Control circuit power supply/main circuit
power supply (24 V DC)
CP30-BA 1P 1-M 10A
Note. For operation characteristics, use an intermediate speed type.
Содержание Melservo MR-J3-100B
Страница 17: ...8 MEMO ...
Страница 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Страница 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Страница 146: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 1 Part 4 Review on Replacement of MR J3W _B with MR J4W2 _B ...
Страница 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Страница 196: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 1 Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ ...
Страница 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Страница 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Страница 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Страница 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Страница 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Страница 589: ...L NA 03127ENG C ...