Part 3: Review on Replacement of MR-J3-_B_ with MR-J4-_B_
3 - 46
MR-J3-_B_
MR-J4-_B_
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PD31 Master-slave operation - Speed limit coefficient on slave
This parameter setting is used with servo amplifier with
software version C1 or later. Check the software version
using Setup software (SETUP221E).
This parameter is used to set an internal speed limit
value coefficient to speed limit command value received
from master axis. This parameter is enabled when this
amplifier is set as slave axis ([Pr. PD15] = "0010").
Convert a decimal value to a hexadecimal value for
input. The maximum value is 500. Setting over 500 will
be 500.
Setting 100 [%] (0064h in hexadecimal) means
multiplication of one.
Setting example: [Pr. PD31 (VLC)] = 0078h (120%), [Pr.
PD32 (VLL)] = 012Ch (300 r/min), and master side
acceleration/deceleration at 1000 [r/min]
0000h
PD31 Master-slave operation - Speed limit coefficient on slave
This parameter is used to set an internal speed limit
value coefficient to speed limit command value received
from master axis.
This parameter is enabled when this amplifier is set as
slave axis ([Pr. PD15] is "_ _ 1 0".). The maximum value
is 500. Setting over 500 will be 500.
Setting 100 [%] means multiplication of one.
Setting example: [Pr. PD31 (VLC)] = 140 [%], [Pr. PD32
(VLL)] = 300 [r/min], and master side
acceleration/deceleration at 1000 [r/min]
VLL
0
Speed command from
master side × VLC [%]
Speed limit value of
slave side
300 r/min
1400 r/min
1000 r/min
Speed limit command
from master side (driver
communication)
Speed (r/min)
This parameter setting is used with servo amplifier with
software version A8 or later.
0
PD32 Master-slave operation - Speed limit adjusted value on
slave
This parameter setting is used with servo amplifier with
software version C1 or later. Check the software version
using Setup software (SETUP221E).
This parameter is used to set a minimum value for
internal speed limit value.
This parameter is enabled when this amplifier is set as
slave axis ([Pr. PD15] = "0010"). Convert a decimal value
to a hexadecimal value for input. The speed limit value
will not be this setting value or lower.
This parameter ensures torque control range at low
speed driving (avoid area likely to reach speed limit). Set
100 to 500 [r/min] normally as a reference.
Refer to [Pr. PD31] for the setting example.
0000h PD32 Master-slave
operation
- Speed limit adjusted value on
slave
This parameter is used to set a minimum value for
internal speed limit value.
This parameter is enabled when this amplifier is set as
slave axis ([Pr. PD15] is "_ _ 1 0".). The speed limit value
will not be this setting value or lower.
This parameter ensures torque control range at low
speed driving (avoid area likely to reach speed limit). Set
100 to 500 [r/min] normally as a reference.
Refer to [Pr. PD31] for the setting example.
This parameter setting is used with servo amplifier with
software version A8 or later.
0
VLL
0
Speed command
from master side
Speed limit value of
slave side
300r/min
1200r/min
1000r/min
S
peed (r/
m
in
)
Speed limit command
from master side (driver
communication)
Содержание Melservo MR-J3-100B
Страница 17: ...8 MEMO ...
Страница 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Страница 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Страница 146: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 1 Part 4 Review on Replacement of MR J3W _B with MR J4W2 _B ...
Страница 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Страница 196: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 1 Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ ...
Страница 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Страница 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Страница 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Страница 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Страница 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Страница 589: ...L NA 03127ENG C ...